Improved exercise test accuracy using discriminant function analysis and "recovery ST slope".

M Rodriguez1, I Moussa, J Froning, M Kochumian, V F Froelicher.   

Abstract

The objective of the study was to optimize the accuracy of the exercise test for predicting the presence of significant angiographic coronary artery disease. A retrospective analysis of stored digital exercise electrocardiographic data on 147 men who had undergone exercise testing and cardiac catheterization was performed. With significant coronary artery disease defined as > or = 70% stenosis, 95 patients had one or more vessel(s) diseased. None were receiving digoxin, had a myocardial infarction or previous coronary artery bypass graft, or exhibited left bundle branch block, left ventricular hypertrophy, Q waves, or ST depression on their resting electrocardiogram. Analysis was performed using the authors' averaging and measurement software at rest and at each 30 seconds throughout the exercise and recovery in leads II, V2, and V5. Discriminant function analysis was used to analyze pretest variables, as well as hemodynamic and electrocardiographic changes and symptoms during exercise. A discriminant function score was developed and compared to other treadmill scores. The setting was a 1,000 bed Veterans Affairs Medical Center (Long Beach, CA). Discriminant function analysis chose age, smoking status, presenting chest pain characteristics, and lead V5 ST slope in recovery to have independent power for separating those with and without coronary artery disease. A discriminant function score using these four variables was used to form a receiver operating characteristics curve (and derive receiver operating characteristics curve areas) for comparison to other exercise test methods and scores: (discriminant function score = .81; slope 3.5 minutes into recovery in lead V5 = .73; traditional ST amplitude method = .72; ST60/HR index (amplitude of ST depression 60 ms after the J point/delta heart rate) = .66; traditional ST amplitude/HR index (traditional method/delta heart rate) = .75; Hollenberg score = .68; Hollenberg areas only = .66; and ST integral = .66. Receiver operating characteristics curve analysis revealed a trend for the discriminant function score to be superior to all other measurements and scores. Recovery ST slope in lead V5 performed as well as or better than all other electrocardiographic criteria or treadmill scores except for the authors' discriminant function score.

Entities:  

Mesh:

Year:  1993        PMID: 8409814     DOI: 10.1016/0022-0736(93)90039-g

Source DB:  PubMed          Journal:  J Electrocardiol        ISSN: 0022-0736            Impact factor:   1.438


  3 in total

1.  Comparison of a two-lead, computerized, resting ECG signal analysis device, the MultiFunction-CardioGram or MCG (a.k.a. 3DMP), to quantitative coronary angiography for the detection of relevant coronary artery stenosis (>70%) - a meta-analysis of all published trials performed and analyzed in the US.

Authors:  John E Strobeck; Joseph T Shen; Binoy Singh; Kotaro Obunai; Charles Miceli; Howard Sacher; Franz Ritucci; Michael Imhoff
Journal:  Int J Med Sci       Date:  2009-04-07       Impact factor: 3.738

2.  Computerized two-lead resting ECG analysis for the detection of coronary artery stenosis after coronary revascularization.

Authors:  Eberhard Grube; Andreas Bootsveld; Lutz Buellesfeld; Seyrani Yuecel; Joseph T Shen; Michael Imhoff
Journal:  Int J Med Sci       Date:  2008-03-02       Impact factor: 3.738

3.  Computerized two-lead resting ECG analysis for the detection of coronary artery stenosis.

Authors:  Eberhard Grube; Andreas Bootsveld; Seyrani Yuecel; Joseph T Shen; Michael Imhoff
Journal:  Int J Med Sci       Date:  2007-10-16       Impact factor: 3.738