Literature DB >> 8409039

Radiation risk to patients from percutaneous transluminal coronary angioplasty.

P L Pattee1, P C Johns, R J Chambers.   

Abstract

OBJECTIVES: This retrospective study sought to estimate patient radiation exposure during percutaneous transluminal coronary angioplasty, the corresponding organ doses and the resulting cancer mortality risk. Patient demographic data were also examined.
BACKGROUND: Coronary angioplasty is commonly used as an intervention for coronary atherosclerosis, and repeated application in the same patient is now common. The combined use of fluoroscopy and cineradiography in this complicated, delicate and, hence, lengthy procedure induced us to investigate the patient radiation exposures and resulting risks.
METHODS: All complete records for angioplasty procedures performed over a 3-year period were entered into a data base. The data comprised 1,893 procedures performed in a total of 1,503 patients, of whom 21% had two or more procedures in the 3-year period. Fluoroscopy time was converted to entrance exposures, assuming a rate of 520 muC kg-1 min-1 (2.0 R min-1). Cineradiographic film lengths were determined for a smaller number of procedures (200) and converted to exposures at 7.7 muC kg-1 frame-1 (30 mR frame-1). In addition, fluoroscopy and cineradiographic times and, hence, exposures for 91 diagnostic angiograms performed in these patients were obtained. Exposures were converted to organ doses using the Monte Carlo results of the Rosenstein group and then to cancer mortality risks using the latest rates of the International Commission on Radiological Protection.
RESULTS: The mean age was 56.0 years; men constituted 77.5% of the patients. Radiation doses varied considerably owing to a large spread in exposure times (e.g., fluoroscopy time per angioplasty case averaged 19 min but for some cases exceeded 1 h). The average patient skin entrance exposure per angioplasty procedure was 32.0 mC kg-1 (124 R), of which 69.7% was from cineradiography. The resulting cancer mortality risk per angioplasty procedure is approximately 8 x 10(-4).
CONCLUSIONS: The skin exposures estimated for angioplasty are on average higher than for other X-ray procedures. The cancer mortality risk does not exceed the mortality risk of bypass surgery. Good professional practice requires maximization of the benefit/risk ratio through quality assurance in all aspects of the procedure.

Entities:  

Mesh:

Year:  1993        PMID: 8409039     DOI: 10.1016/0735-1097(93)90414-v

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  6 in total

Review 1.  [Intravascular irradiation in the combined therapy and prevention of restenosis. Overview].

Authors:  D Baumgart; U Quast; R Erbel
Journal:  Herz       Date:  1997-12       Impact factor: 1.443

Review 2.  [Cutaneous radiation syndrome after accidental skin exposure to ionizing radiation].

Authors:  R U Peter
Journal:  Hautarzt       Date:  2013-12       Impact factor: 0.751

Review 3.  [Intracoronary brachytherapy with strontium/yttrium-90. Initial experiences in Germany].

Authors:  S Silber; P von Rottkay; A Gielow; A Schneider; A Bauer; H Schöfer
Journal:  Herz       Date:  1998-09       Impact factor: 1.443

4.  Thoracic radionecrosis following repeated cardiac catheterization.

Authors:  Borut Banic; Bernhard Meier; Andrej Banic; Christian Weinand
Journal:  Radiol Res Pract       Date:  2010-12-15

5.  Procedural determinants of fluoroscopy time in patients undergoing cardiac catheterization.

Authors:  Syed Fayaz Mujtaba; Tahir Saghir; Jawaid Akbar Sial; Nadeem Hassan Rizvi
Journal:  Pak J Med Sci       Date:  2019 Jan-Feb       Impact factor: 1.088

6.  Patient radiation doses in interventional cardiology procedures.

Authors:  Ioannis Pantos; Georgios Patatoukas; Demosthenes G Katritsis; Efstathios Efstathopoulos
Journal:  Curr Cardiol Rev       Date:  2009-01
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.