Literature DB >> 8408412

Characterization of vitamin D3 metabolites using continuous-flow fast atom bombardment tandem mass spectrometry and high-performance liquid chromatography.

B Yeung1, P Vouros, G S Reddy.   

Abstract

A mass spectrometric method for the detection of vitamin D3 metabolites is described. This method involves the derivatization of the metabolites by cycloaddition with 4-phenyl-1,2,4-triazoline-3,5-dione, followed by their characterization by continuous-flow fast atom bombardment (CF-FAB) tandem mass spectrometry (MS-MS) and high-performance liquid chromatography (HPLC). Using HPLC, this derivatization has been shown to increase the UV detectability of 25-hydroxyvitamin D3 by about 5-fold. The FAB spectra of the adducts are dominated by peaks corresponding to a protonated molecule and a fragment ion derived in part from the loss of the side chain. Multiple reaction monitoring (MRM) of this transition by MS-MS may be utilized for trace level analysis of vitamin D metabolites. Sample introduction by flow injection yields detection limits in the low nanogram to high picogram range, whereas the use of on-line capillary LC has been found to decrease the detection limits to the low picogram level.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8408412     DOI: 10.1016/0021-9673(93)80625-i

Source DB:  PubMed          Journal:  J Chromatogr


  5 in total

1.  Quantitative determination of vitamin D metabolites in plasma using UHPLC-MS/MS.

Authors:  Shujing Ding; Inez Schoenmakers; Kerry Jones; Albert Koulman; Ann Prentice; Dietrich A Volmer
Journal:  Anal Bioanal Chem       Date:  2010-07-14       Impact factor: 4.142

2.  Quantification of vitamin D and 25-hydroxyvitamin D in soft tissues by liquid chromatography-tandem mass spectrometry.

Authors:  Tristan E Lipkie; Amber Janasch; Bruce R Cooper; Emily E Hohman; Connie M Weaver; Mario G Ferruzzi
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2013-06-06       Impact factor: 3.205

3.  Simultaneous Quantification of 25-Hydroxyvitamin D3 and 24,25-Dihydroxyvitamin D3 in Rats Shows Strong Correlations between Serum and Brain Tissue Levels.

Authors:  Ying Xue; Xin He; Huan-De Li; Yang Deng; Miao Yan; Hua-Lin Cai; Mi-Mi Tang; Rui-Li Dang; Pei Jiang
Journal:  Int J Endocrinol       Date:  2015-12-02       Impact factor: 3.257

4.  An ultrasensitive UHPLC-ESI-MS/MS method augmented with a controlled microwave derivatization reaction for quantitation of vitamin D3 and its major metabolites in COVID-19 patients.

Authors:  Sameh A Ahmed; Hani M J Khojah; Sultan S Al-Thagfan; Yaser M Alahmadi; Yasser A Mohammed
Journal:  Talanta       Date:  2022-04-22       Impact factor: 6.556

5.  Using gas chromatography and mass spectrometry to determine 25-hydroxyvitamin D levels for clinical assessment of vitamin D deficiency.

Authors:  Ming-Yeh Yang; Ching-Yuan Huang; Tina H T Chiu; Kai-Chih Chang; Ming-Nan Lin; Liang-Yü Chen; Anren Hu
Journal:  J Food Drug Anal       Date:  2019-01-08       Impact factor: 6.157

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.