| Literature DB >> 840195 |
J B Smathers, V A Otte, A R Smith, P R Almond, F H Attix, J J Spokas, W M Quam, L J Goodman.
Abstract
In recent years, the use of tissue-equivalent materials has become quite common in fast-neutron dosimetry, with the A-150 plastic developed by Shonka et al. probably the most popular. Information on this specific plastic is scantily reported in the literature and as a consequence a preponderance of authors unknowingly reference an article by Shonka describing an early version of a tissue substitute plastic but having a different elemental composition than the present A-150 formulation. We have reviewed the results of 21 chemical analyses which have occurred over a time span of four years on a total of 14 samples of A-150 plastic and based on these data and the formulation of the plastic, have arrived at a suggested composition for A-150 tissue-equivalent plastic. The ambiguities of water absorption by nylon, one of the components of the plastic, and the uncertainty this reflects in the composition of the plastic were evaluated.Entities:
Mesh:
Substances:
Year: 1977 PMID: 840195 DOI: 10.1118/1.594380
Source DB: PubMed Journal: Med Phys ISSN: 0094-2405 Impact factor: 4.071