Literature DB >> 8400555

Comparison of cerebral artery blood flow measurements with gated cine and ungated phase-contrast techniques.

D R Enzmann1, M P Marks, N J Pelc.   

Abstract

Cine phase-contrast (PC) magnetic resonance (MR) pulse sequences have been used to measure blood flow in a variety of vessels. Because the cine PC sequence is time-consuming, this prospective study was undertaken to compare it with an ungated PC technique for measuring average blood flow in individual cerebral arteries to potentially achieve substantial time savings. The following cerebral arteries were studied in 10 healthy volunteers: carotid, basilar, middle cerebral, anterior cerebral, and posterior cerebral. Imaging planes were placed perpendicular to the vessel of interest, and velocity encoding, ranging from 40 to 250 cm/sec, was matched to individual arteries. Good correlation between cine and ungated PC blood flow measurements was obtained for both high- and low-flow vessels, with an overall correlation coefficient of .978. The ungated PC sequence, because of its short imaging time, allows measurement of the blood volume flow rate in the circle of Willis in approximately 20 minutes, a clinically acceptable time.

Entities:  

Mesh:

Year:  1993        PMID: 8400555     DOI: 10.1002/jmri.1880030504

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  13 in total

1.  Time-resolved 3D quantitative flow MRI of the major intracranial vessels: initial experience and comparative evaluation at 1.5T and 3.0T in combination with parallel imaging.

Authors:  Roland Bammer; Thomas A Hope; Murat Aksoy; Marcus T Alley
Journal:  Magn Reson Med       Date:  2007-01       Impact factor: 4.668

2.  Regional cerebral blood flow using quantitative MR angiography.

Authors:  M Zhao; S Amin-Hanjani; S Ruland; A P Curcio; L Ostergren; F T Charbel
Journal:  AJNR Am J Neuroradiol       Date:  2007-09       Impact factor: 3.825

3.  Quantitative Flow Imaging in Human Umbilical Vessels In Utero Using Nongated 2D Phase Contrast MRI.

Authors:  Uday Krishnamurthy; Brijesh K Yadav; Pavan K Jella; Ewart Mark Haacke; Edgar Hernandez-Andrade; Swati Mody; Lami Yeo; Sonia S Hassan; Roberto Romero; Jaladhar Neelavalli
Journal:  J Magn Reson Imaging       Date:  2017-12-23       Impact factor: 4.813

4.  Measurement of cerebral blood flow using phase contrast magnetic resonance imaging and duplex ultrasonography.

Authors:  Muhammad Ayaz Khan; Jie Liu; Takashi Tarumi; Justin Stevan Lawley; Peiying Liu; David C Zhu; Hanzhang Lu; Rong Zhang
Journal:  J Cereb Blood Flow Metab       Date:  2016-07-20       Impact factor: 6.200

5.  Quantitation of flow in the superior sagittal sinus performed with cine phase-contrast MR imaging of healthy and achondroplastic children.

Authors:  N Hirabuki; Y Watanabe; T Mano; N Fujita; H Tanaka; T Ueguchi; H Nakamura
Journal:  AJNR Am J Neuroradiol       Date:  2000-09       Impact factor: 3.825

6.  The effects of aortic coarctation on cerebral hemodynamics and its importance in the etiopathogenesis of intracranial aneurysms.

Authors:  Pankaj K Singh; Alberto Marzo; Cristina Staicu; Matt G William; Iain Wilkinson; Patricia V Lawford; Daniel A Rufenacht; Philippe Bijlenga; Alejandro F Frangi; Rodney Hose; Umang J Patel; Stuart C Coley
Journal:  J Vasc Interv Neurol       Date:  2010-01

7.  Cerebral metabolism and vascular reactivity during breath-hold and hypoxic challenge in freedivers and healthy controls.

Authors:  Mark B Vestergaard; Henrik Bw Larsson
Journal:  J Cereb Blood Flow Metab       Date:  2017-11-03       Impact factor: 6.200

Review 8.  Non-Invasive Evaluation of Cerebral Microvasculature Using Pre-Clinical MRI: Principles, Advantages and Limitations.

Authors:  Bram Callewaert; Elizabeth A V Jones; Uwe Himmelreich; Willy Gsell
Journal:  Diagnostics (Basel)       Date:  2021-05-21

9.  Cerebral Blood and CSF Flow Patterns in Patients Diagnosed for Cerebral Venous Thrombosis - An Observational Study.

Authors:  Souraya Elsankari; Marek Czosnyka; Pierre Lehmann; Marc-Etienne Meyer; Hervé Deramond; Olivier Balédent
Journal:  J Clin Imaging Sci       Date:  2012-07-28

10.  Comparison of global cerebral blood flow measured by phase-contrast mapping MRI with 15 O-H2 O positron emission tomography.

Authors:  Mark Bitsch Vestergaard; Ulrich Lindberg; Niels Jacob Aachmann-Andersen; Kristian Lisbjerg; Søren Just Christensen; Peter Rasmussen; Niels Vidiendal Olsen; Ian Law; Henrik Bo Wiberg Larsson; Otto Mølby Henriksen
Journal:  J Magn Reson Imaging       Date:  2016-09-13       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.