Challenge to the concept that UHMWPE acetabular components oxidize in vivo.

S P James1, S Blazka, E W Merrill, M Jasty, K R Lee, C R Bragdon, W H Harris.   

Abstract

Severe wear of the ultra-high molecular weight polyethylene (UHMWPE) components of total joint replacements limits their long-term success. In previous studies, the infrared spectra obtained on retrieved UHMWPE components were interpreted as evidence that the UHMWPE oxidizes in vivo. In direct contrast, infrared spectroscopy of the retrieved UHMWPE acetabular components examined in this study demonstrated adsorbed esterified fatty acids, readily extractable by hexane, and no substantial evidence of in vivo oxidation. This emphasizes that special care must be taken when using infrared spectroscopy to assess retrieved components.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8399960     DOI: 10.1016/0142-9612(93)90062-7

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  6 in total

1.  Migration stability of alpha-tocopherol in irradiated UHMWPE.

Authors:  Ebru Oral; Keith K Wannomae; Shannon L Rowell; Orhun Kamil Muratoglu
Journal:  Biomaterials       Date:  2005-12-02       Impact factor: 12.479

2.  On the assessment of oxidative and microstructural changes after in vivo degradation of historical UHMWPE knee components by means of vibrational spectroscopies and nanoindentation.

Authors:  Francisco J Medel; Clare M Rimnac; Steven M Kurtz
Journal:  J Biomed Mater Res A       Date:  2009-05       Impact factor: 4.396

3.  Do first-generation highly crosslinked polyethylenes oxidize in vivo?

Authors:  Daniel MacDonald; Ashlyn Sakona; Allyson Ianuzzi; Clare M Rimnac; Steven M Kurtz
Journal:  Clin Orthop Relat Res       Date:  2011-08       Impact factor: 4.176

4.  A Novel Technique for Assessing Antioxidant Concentration in Retrieved UHMWPE.

Authors:  Barbara H Currier; Douglas W Van Citters
Journal:  Clin Orthop Relat Res       Date:  2017-05       Impact factor: 4.176

5.  Retrieval analysis of sequentially annealed highly crosslinked polyethylene used in total hip arthroplasty.

Authors:  Steven M Kurtz; Daniel W MacDonald; Michael A Mont; Javad Parvizi; Arthur L Malkani; William Hozack
Journal:  Clin Orthop Relat Res       Date:  2015-03       Impact factor: 4.176

6.  Retrieval analysis of Harris-Galante I and II acetabular liners in situ for more than 10 years.

Authors:  Keisha French; Rebecca Moore; Heather Gawel; Steven M Kurtz; Matthew J Kraay; Ke Xie; Victor M Goldberg; Clare M Rimnac
Journal:  Acta Orthop       Date:  2012-08-10       Impact factor: 3.717

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.