PDPH in obstetric anesthesia: comparison of 24-gauge Sprotte and 25-gauge Quincke needles and effect of subarachnoid administration of fentanyl.

A Devcic1, J Sprung, S Patel, R Kettler, A Maitra-D'Cruze.   

Abstract

BACKGROUND AND OBJECTIVES: Postdural puncture headache (PDPH) is a frequent complication of spinal anesthesia. Some investigators have recommended the use of the Sprotte needle to reduce the incidence of this serious complication. This study prospectively compared the incidence of PDPH with two spinal needles of different size and design: the 24-gauge Sprotte (noncutting point) versus the 25-gauge Quincke (diamond, cutting point). The hypothesis that subarachnoid fentanyl will reduce the incidence of PDPH, as suggested in the literature, was also studied.
METHODS: Only patients for emergency or elective cesarean delivery were studied. One hundred ninety four patients were randomly assigned to receive spinal anesthesia with one of the two needles (Sprotte, n = 96; Quincke, n = 98). Simultaneously, each patient was assigned to receive hyperbaric 0.75% bupivacaine local anesthetic or a combination of the same concentration of local anesthetic with 20 micrograms of fentanyl (Sprotte with fentanyl, n = 47; Sprotte without fentanyl, n = 49; Quincke with fentanyl, n = 49; Quincke without fentanyl, n = 49). All patients were evaluated during the first 4 postoperative days, and follow-up telephone interviews were conducted 3 weeks after discharge.
RESULTS: Four patients (4.2%) in the Sprotte group and seven (7.1%) in the Quincke group developed PDPH. Three out of four patients with headache in the Sprotte and four out of seven in the Quincke group received fentanyl as an adjunct for spinal anesthesia. Two patients in the Sprotte group required an epidural blood patch as a therapy for PDPH. Two patients in the Quincke group had severe headache and required an epidural blood patch.
CONCLUSIONS: In the current study, the use of the 24-gauge Sprotte spinal needle resulted in a low incidence of severe PDPH, but was not significantly different when compared with the use of a 25-gauge Quincke needle (oriented parallel to the longitudinal dural fibers). The addition of fentanyl to hyperbaric bupivacaine spinal anesthesia did not reduce the risk of PDPH.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8398955

Source DB:  PubMed          Journal:  Reg Anesth        ISSN: 0146-521X


  5 in total

1.  Neuraxial morphine after unintentional dural puncture is not associated with reduced postdural puncture headache in obstetric patients.

Authors:  Molly E Brinser; David L Seng; Gordon L Mandell; Jonathan Waters; Patricia L Dalby; Grace Lim
Journal:  J Clin Anesth       Date:  2018-09-11       Impact factor: 9.452

Review 2.  [Recent standards in management of obstetric anesthesia].

Authors:  Maximiliaan van Erp; Clemens Ortner; Stefan Jochberger; Klaus Ulrich Klein
Journal:  Wien Med Wochenschr       Date:  2017-07-25

Review 3.  Needle gauge and tip designs for preventing post-dural puncture headache (PDPH).

Authors:  Ingrid Arevalo-Rodriguez; Luis Muñoz; Natalia Godoy-Casasbuenas; Agustín Ciapponi; Jimmy J Arevalo; Sabine Boogaard; Marta Roqué I Figuls
Journal:  Cochrane Database Syst Rev       Date:  2017-04-07

4.  Comparison of cutting and pencil-point spinal needle in spinal anesthesia regarding postdural puncture headache: A meta-analysis.

Authors:  Hong Xu; Yang Liu; WenYe Song; ShunLi Kan; FeiFei Liu; Di Zhang; GuangZhi Ning; ShiQing Feng
Journal:  Medicine (Baltimore)       Date:  2017-04       Impact factor: 1.889

5.  Effect of intrathecal fentanyl on the incidence, severity, and duration of postdural puncture headache in parturients undergoing caesarean section: A randomised controlled trial.

Authors:  Wegdan A Ali; Mo'men Mohammed; Ahmed R Abdelraheim
Journal:  Indian J Anaesth       Date:  2020-11-01
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.