Radiopaque marker in the tilting disc of the Björk-Shiley heart valve. Evaluation of in vivo prosthetic valve function by cineradiography.

V O Björk, A Henze, T Hindmarsh.   

Abstract

This paper describes a new, noninvasive method for evaluating the in vivo function of the Björk-Shiley tilting disc valve in the aortic, mitral, and tricuspid positions. The tilting disc was equipped with a ring-shaped radiopaque marker, which permits visualization of the motion of the disc by both cineradiographic and fluoroscopic studies. A beam direction corresponding to the axis of motion of the disc should be sought for calculation of the prosthetic opening angle, whereas prostehtic valve closure is demonstrated by a beam direction deviating 20 to 30 degrees from the valve ring plane. Complete opening to 60 degrees and closure of the prosthetic valve, indicating free motility of the tilting disc, were confirmed by cineradiograms. The error of estimation of the in vivo opening angle is small with deviations of less than 15 degrees from the ideal beam direction and negligible for opening angles approaching 60 degrees. Deviations in two planes simultaneously cause less error than deviation in one plane. The radiopaque marker was designed to detect mechanical valve failure owing to thrombotic obstruction. The incidence of this particular complication was 8.1 per 100 patient-years after aortic valve replacement without anticoagulation treatment. With anticoagulation, this incidence was zero after aortic and 2.5 after mitral valve replacement. In our clinical experience to date, which comprises over 1,250 implants, we have not encountered a single case of primary mechanical valve dysfunction. Our current program includes a change-over to the radiopaque tilting-disc model of the Björk-Shiley prosthesis, which was introduced at this clinic in March, 1975.

Entities:  

Mesh:

Year:  1977        PMID: 839847

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  3 in total

Review 1.  EMT-inducing biomaterials for heart valve engineering: taking cues from developmental biology.

Authors:  M K Sewell-Loftin; Young Wook Chun; Ali Khademhosseini; W David Merryman
Journal:  J Cardiovasc Transl Res       Date:  2011-07-13       Impact factor: 4.132

2.  Thrombotic obstruction of the Björk-Shiley valve: the Glasgow experience.

Authors:  S J Ryder; H Bradley; J J Brannan; M A Turner; W H Bain
Journal:  Thorax       Date:  1984-07       Impact factor: 9.139

3.  Long-term experience with the Bjork-Shiley Monostrut tilting disc valve.

Authors:  Hyuk Ahn; Kyung Hwan Kim; Dong Jin Kim; Dong Seop Jeong
Journal:  J Korean Med Sci       Date:  2007-12       Impact factor: 2.153

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.