| Literature DB >> 8392032 |
P J Livesley1, V M Srivastiva, M Needoff, H G Prince, A M Moulton.
Abstract
A prospective clinical trial has been conducted comparing the use of a hydoxyapatite-coated bipolar hemiarthroplasty and an uncemented bipolar prosthesis in the treatment of displaced subcapital fractures of the femur. The trial was conducted over 1 year, 82 patients suffering displaced subcapital fractures of the femur were included. The patients were followed up for 1 year postoperatively. The functional result was significantly superior in the hydroxyapatite-coated group. Characteristic changes were found on radiographs both proximally and distally, indicating that distal stem fixation with proximal stress shielding had occurred.Entities:
Mesh:
Substances:
Year: 1993 PMID: 8392032 DOI: 10.1016/0020-1383(93)90176-7
Source DB: PubMed Journal: Injury ISSN: 0020-1383 Impact factor: 2.586