Literature DB >> 8390530

Reproducibility of ambulatory and clinic blood pressure measurements in elderly hypertensive subjects.

M D Fotherby1, J F Potter.   

Abstract

OBJECTIVES: To compare the reproducibility of clinic and ambulatory blood pressure measurements in elderly hypertensive subjects.
SUBJECTS: Twenty-two untreated elderly hypertensives, with a clinic systolic blood pressure (SBP) > 160 mmHg and/or diastolic blood pressure (DBP) > 95 mmHg, and a mean age of 76 years (range 66-86).
METHODS: Following three supine clinic blood pressure readings the subjects underwent 24-h non-invasive ambulatory blood pressure monitoring, measurements being taken at 20-min intervals from 0700 to 2200 h and at 30-min intervals from 2200 to 0700 h. Measurements were repeated during a further visit at a median interval of 10 weeks (range 1-10 months).
RESULTS: Daytime ambulatory SBP levels were 20 mmHg (95% confidence interval 14-27 mmHg, P < 0.001) lower than clinic SBP, although DBP values were similar. The mean 24-h ambulatory SBP and DBP reproducibility [assessed by the standard deviation of differences (SDD) between visits] was significantly better than that for mean clinic blood pressure (SBP 6.3 versus 17.4 mmHg, P < 0.001; DBP 4.8 versus 7.0 mmHg, respectively, P < 0.05). With daytime defined as 1000-1959 h, the SDD between visits was 12.4 mmHg for SBP and 8.3 mmHg for DBP, but with daytime defined as 0700-2159 h, the SDD fell to 6.0 mmHg for SBP and 4.8 mmHg for DBP, values almost identical to those obtained with full 24-h blood pressure monitoring. There was no difference in night-time blood pressure reproducibility, whether night-time was defined as 2400-0559 h or 2200-0659 h.
CONCLUSIONS: Both 24-h and daytime ambulatory blood pressure monitoring significantly improve the reproducibility of blood pressure measurements compared with clinic blood pressure readings in elderly hypertensive subjects. Increasing the number of daytime blood pressure readings by 50% (from 30 to 45) reduced the variability of blood pressure measurement by 50%. Twenty-four-hour ambulatory blood pressure monitoring is of value in obtaining reproducible blood pressure measurements in elderly hypertensive subjects. However, more than 30 readings are needed during a daytime recording to significantly reduce variability compared with repeated clinic measurements, although night-time variability is not significantly affected if the number of readings is reduced to 12 over a 6-h period.

Entities:  

Mesh:

Year:  1993        PMID: 8390530     DOI: 10.1097/00004872-199305000-00014

Source DB:  PubMed          Journal:  J Hypertens        ISSN: 0263-6352            Impact factor:   4.844


  9 in total

1.  Is Isolated Nocturnal Hypertension A Reproducible Phenotype?

Authors:  Marwah Abdalla; Jeff Goldsmith; Paul Muntner; Keith M Diaz; Kristi Reynolds; Joseph E Schwartz; Daichi Shimbo
Journal:  Am J Hypertens       Date:  2015-04-22       Impact factor: 2.689

2.  Intensified monitoring of circadian blood pressure and heart rate before and after intravitreous injection of bevacizumab: preliminary findings of a pilot study.

Authors:  Focke Ziemssen; Qi Zhu; Swaantje Peters; Salvatore Grisanti; Mohammed El Wardani; Peter Szurman; Karl U Bartz-Schmidt; Tjalf Ziemssen
Journal:  Int Ophthalmol       Date:  2008-04-17       Impact factor: 2.031

3.  How many self-measured blood pressure readings are needed to estimate hypertensive patients' "true" blood pressure?

Authors:  M P García-Vera; J Sanz
Journal:  J Behav Med       Date:  1999-02

4.  [Accuracy and precision in blood pressure measurement. Comparative study of home self-measurement with measurement in the clinic and out-patient monitoring].

Authors:  J Divisón; A Puras; C Sanchis; L Artigao; J López Abril; E López De Coca; J Massó; B Rodríguez Paños
Journal:  Aten Primaria       Date:  2001-03-31       Impact factor: 1.137

5.  Improving Blood Pressure Control Using Digital Communication Methods in Serbia.

Authors:  Nebojsa Tasic; Danijela Tasic; Zorana Kovacevic; Marko Filipovic; Milan Arsic; Sladjana Bozovic-Ogarevic; Biljana Despotovic; Milovan Bojic; Zlatko Maksimovic; Nebojsa Zdravkovic; Sara Mijailovic; Vladimir Zivkovic; Tamara Nikolic Turnic; Vladimir Jakovljevic
Journal:  Diagnostics (Basel)       Date:  2022-04-06

6.  A series of self-measurements by the patient is a reliable alternative to ambulatory blood pressure measurement.

Authors:  M M Brueren; H J Schouten; P W de Leeuw; G A van Montfrans; J W van Ree
Journal:  Br J Gen Pract       Date:  1998-09       Impact factor: 5.386

7.  Reliability of morning, before-dinner, and at-bedtime home blood pressure measurements in patients with hypertension.

Authors:  Takeshi Fujiwara; Satoshi Hoshide; Hiroshi Kanegae; Masafumi Nishizawa; Kazuomi Kario
Journal:  J Clin Hypertens (Greenwich)       Date:  2018-01-06       Impact factor: 3.738

8.  Novel Triggered Nocturnal Blood Pressure Monitoring for Sleep Apnea Syndrome: Distribution and Reproducibility of Hypoxia-Triggered Nocturnal Blood Pressure Measurements.

Authors:  Mitsuo Kuwabara; Haruna Hamasaki; Naoko Tomitani; Toshikazu Shiga; Kazuomi Kario
Journal:  J Clin Hypertens (Greenwich)       Date:  2016-07-14       Impact factor: 3.738

9.  Dietary sodium and nocturnal blood pressure dipping in normotensive men and women.

Authors:  M S Brian; A Dalpiaz; E L Matthews; S Lennon-Edwards; D G Edwards; W B Farquhar
Journal:  J Hum Hypertens       Date:  2016-08-11       Impact factor: 3.012

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.