Literature DB >> 8390329

Alkalinization improves the quality of lidocaine-fentanyl epidural anaesthesia for caesarean section.

G Capogna1, D Celleno, P Costantino, F Muratori, M Sebastiani, M Baldassini.   

Abstract

This double-blind randomized study of 116 healthy women was undertaken to evaluate whether alkalinization potentiated the analgesic effects of epidural fentanyl-lidocaine for elective Caesarean section. After a test-dose of 3 ml, lidocaine 2% with adrenaline 1:200,000, all patients received 100 micrograms, fentanyl in 5 ml saline and they were then divided into two groups, to receive incremental doses of 5 ml lidocaine 2% with adrenaline 1:200,000 with or without 0.1 mEq.ml-1 sodium bicarbonate, to obtain anaesthesia to T4. The addition of bicarbonate to lidocaine resulted in a mean (SD) pH increase from 6.58 (0.01) to 7.14 (0.02) and in a mean PCO2 increase from 3.8 (0.8) to 345.1 (5.9) mmHg. Onset of sensory analgesia to the S1 segment as well as the interval between the block and the delivery of the baby were shorter in the bicarbonate group (respectively 15.4 (6.9) vs 18.9 (4.8) min and 28.9 (9.5) versus 33.9 (11.8) min; P < 0.01 and 0.05). No differences were noted in the onset to T4 or in the degree of motor block. The percentage of patients experiencing pain during surgery and requiring intravenous analgesics was higher in the group which did not receive bicarbonate (3% vs 16%; P < 0.05). There were no differences in intraoperative maternal side-effects, neonatal outcome or in maternal venous and umbilical venous and arterial lidocaine concentrations between the groups. The concentrations of fentanyl in maternal plasma, umbilical artery, and the umbilical artery to maternal vein ratio were greater in the alkalinized group (P < 0.001).(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8390329     DOI: 10.1007/BF03009511

Source DB:  PubMed          Journal:  Can J Anaesth        ISSN: 0832-610X            Impact factor:   5.063


  28 in total

1.  Comparison of toxicity of intravenously given local anesthetic agents in man.

Authors:  F F FOLDES; R MOLLOY; P G McNALL; L R KOUKAL
Journal:  J Am Med Assoc       Date:  1960-04-02

2.  Anesthesia for cesarean delivery. Part II: epidural anesthesia intrathecal and epidural opioids venous air embolism.

Authors:  S A Lassos; S Datta
Journal:  Int J Obstet Anesth       Date:  1992-09       Impact factor: 2.603

3.  Dependence of lidocaine potency on pH and PCO2.

Authors:  P M Bokesch; S A Raymond; G R Strichartz
Journal:  Anesth Analg       Date:  1987-01       Impact factor: 5.108

4.  29-gauge spinal needles.

Authors:  G Lyons; R Macdonald
Journal:  Br J Anaesth       Date:  1991-08       Impact factor: 9.166

5.  Fentanyl-induced ventilatory depression: effects of age.

Authors:  R E Hertzka; I S Gauntlett; D M Fisher; M J Spellman
Journal:  Anesthesiology       Date:  1989-02       Impact factor: 7.892

6.  Comparison of pH-adjusted lidocaine solutions for epidural anesthesia.

Authors:  C A DiFazio; H Carron; K R Grosslight; J C Moscicki; W R Bolding; R A Johns
Journal:  Anesth Analg       Date:  1986-07       Impact factor: 5.108

7.  There is only a limited place for spinals in obstetrics.

Authors:  J S Crawford
Journal:  Acta Anaesthesiol Belg       Date:  1988

8.  A double-blind comparison of epidural bupivacaine and bupivacaine-fentanyl for caesarean section.

Authors:  M J Paech; M D Westmore; H M Speirs
Journal:  Anaesth Intensive Care       Date:  1990-02       Impact factor: 1.669

9.  Epidural mepivacaine for cesarean section: effects of a pH-adjusted solution.

Authors:  G Capogna; D Celleno; G Varrassi; M Emanuelli; M Sebastiani; F Muratori; G Cipriani; M Tomassetti
Journal:  J Clin Anesth       Date:  1991 May-Jun       Impact factor: 9.452

10.  A new neurologic and adaptive capacity scoring system for evaluating obstetric medications in full-term newborns.

Authors:  C Amiel-Tison; G Barrier; S M Shnider; G Levinson; S C Hughes; S J Stefani
Journal:  Anesthesiology       Date:  1982-05       Impact factor: 7.892

View more
  1 in total

1.  Pain perception with pH buffered peribulbar anaesthesia: a pilot study.

Authors:  M C Minasian; A C Ionides; R Fernando; C C Davey
Journal:  Br J Ophthalmol       Date:  2000-09       Impact factor: 4.638

  1 in total