Literature DB >> 8386489

Assessment of in situ renal transplant viability by 31P-MRS: experimental study in canines.

P N Bretan1, D B Vigneron, H Hricak, D C Price, T S Yen, J A Luo, E A Tanagho, T L James.   

Abstract

In 14 in situ canine renal transplants, intracellular phosphorus metabolites were evaluated by phosphorus-31 magnetic resonance spectroscopy (31P-MRS), performed using surface coils to investigate the usefulness of this technique for assessing renal viability in situ. Group I control kidneys (n = 5) were autografts, as were Group II (n = 5) kidneys: the latter group were subjected to surgically induced vascular ischemia and thrombosis. Group III kidneys (n = 4) were rejecting allografts. Renal flow and function, as measured by 99mTc-DTPA, and findings on histologic examination were correlated with 31P-MRS spectra. Group I kidneys showed excellent viability on both 99mTc-DTPA studies and biopsy evaluation, and their 31P-MRS-derived ratios of phosphomonoesters/inorganic phosphate (PME/Pi) and adenosine triphosphate/Pi (ATP/Pi) were high (1.32 +/- 0.23 and 0.90 +/- 0.36, respectively). In contrast, Group II kidneys demonstrated poor flow and function, histologic evidence of severe ischemia from venous and arterial thrombosis, and significantly (P < 0.005) less viability than controls, as monitored by 31P-MRS PME/Pi (0.58 +/- 0.30) and ATP/Pi (0.20 +/- 0.13) ratios. Group III kidneys also demonstrated poor flow and function with 99mTc-DTPA, and the associated histologically injury was noted to be caused by accelerated rejection and severe vascular damage. PME/Pi (0.24 +/- 0.22) and ATP/Pi (0.10 +/- 0.01) ratios were also significantly (P < 0.005) less than those in controls, reflecting nonviability. The 31P-MRS-derived PME/Pi and ATP/Pi ratios enable a qualitative noninvasive assessment of blood flow-dependent renal viability, but with currently used localization techniques the differentiation between severe ischemia and severe acute rejection was not possible.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8386489

Source DB:  PubMed          Journal:  Am Surg        ISSN: 0003-1348            Impact factor:   0.688


  1 in total

1.  Detection of ATP by "in line" 31P magnetic resonance spectroscopy during oxygenated hypothermic pulsatile perfusion of pigs' kidneys.

Authors:  Francois Lazeyras; Leo Buhler; Jean-Paul Vallee; Martin Hergt; Antonio Nastasi; Raphael Ruttimann; Philippe Morel; Jean-Bernard Buchs
Journal:  MAGMA       Date:  2012-05-29       Impact factor: 2.310

  1 in total