Literature DB >> 8378523

Dosimetry and measured differential W values of air for heavy ions.

T Kanai1, T Kohno, S Minohara, M Sudou, E Takada, F Soga, K Kawachi, A Fukumura.   

Abstract

Heavy-ion irradiation systems were designed and constructed at two cyclotron facilities in Japan for use in various fields of radiation physics and radiation biology. A 135 MeV/u carbon beam as well as 12 MeV/u carbon and helium-3 beams were first used in experiments. We have established a systematic method for heavy-ion dosimetry at both high and low incident energies involving measurements of fluences. We also obtained differential W values (w) of air for those beams by comparing the results of fluence measurement dosimetry with ionization chamber dosimetry. The differential W values of air were found to be 36.2 +/- 1.0, 34.5 +/- 1.0, and 33.7 +/- 0.9 eV for 6.7 MeV/u carbon ions, 10.3 MeV/u 3He ions, and 129.4 MeV/u carbon ions, respectively. The w value for high-energy heavy ions approaches the W value for high-energy electron or photon beams. In ionization chamber dosimetry for a heavy-ion beam, we found a track-size effect. A difference in the track sizes of heavy ions in the gas and solid phases affected the output current of the ion chamber in the case of high-energy heavy ions.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8378523

Source DB:  PubMed          Journal:  Radiat Res        ISSN: 0033-7587            Impact factor:   2.841


  3 in total

1.  Monte Carlo calculations for absolute dosimetry to determine machine outputs for proton therapy fields.

Authors:  Harald Paganetti
Journal:  Phys Med Biol       Date:  2006-05-17       Impact factor: 3.609

2.  Effects of shielding on the induction of 53BP1 foci and micronuclei after Fe ion exposures.

Authors:  Wentao Hu; Hailong Pei; He Li; Nan Ding; Jinpeng He; Jufang Wang; Yoshiya Furusawa; Ryoichi Hirayama; Yoshitaka Matsumoto; Cuihua Liu; Yinghui Li; Tetsuya Kawata; Guangming Zhou
Journal:  J Radiat Res       Date:  2013-05-31       Impact factor: 2.724

3.  Comparison of the repair of potentially lethal damage after low- and high-LET radiation exposure, assessed from the kinetics and fidelity of chromosome rejoining in normal human fibroblasts.

Authors:  Cuihua Liu; Tetsuya Kawata; Guangming Zhou; Yoshiya Furusawa; Ryuichi Kota; Atsuhiro Kumabe; Shinya Sutani; Junichi Fukada; Masayo Mishima; Naoyuki Shigematsu; Kerry George; Francis Cucinotta
Journal:  J Radiat Res       Date:  2013-05-14       Impact factor: 2.724

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.