[Experience with the Ender hooked plate in the management of 42 scaphoid pseudarthroses].

P Stanković1, H Burchhardt.   

Abstract

To treat the pseudarthrosis of scaphoid, there exist many operative procedures. We describe the method of H. G. Ender: A hook plate fixes the main bone fragments and exerts a pressure on the in-between lying bone transplant. We report on 42 patients operated on using the Ender-plate. In 39 cases a follow-up was possible. 95% of the patients had a consolidation of the bone, in two cases a further operation was required. 36 patients complained preoperatively of pain during exercise and only seven patients had the same complaints after the operation. In some cases, a minor reduction of the motion had to be taken into account to achieve painfree movement.

Entities:  

Mesh:

Year:  1993        PMID: 8375762

Source DB:  PubMed          Journal:  Handchir Mikrochir Plast Chir        ISSN: 0722-1819            Impact factor:   1.018


  3 in total

1.  Clinical outcome after alternative treatment of scaphoid fractures and nonunions.

Authors:  A L Sander; K Sommer; D Schäf; C Braun; I Marzi; T Pohlemann; J Frank
Journal:  Eur J Trauma Emerg Surg       Date:  2017-02-27       Impact factor: 3.693

2.  Angular Stable Miniplate Fixation of Chronic Unstable Scaphoid Nonunion.

Authors:  Philip M J Schormans; Peter R G Brink; Martijn Poeze; Pascal F W Hannemann
Journal:  J Wrist Surg       Date:  2017-05-10

3.  Anatomic Locking Plate Fixation for Scaphoid Nonunion.

Authors:  Joshua Mirrer; Just Yeung; Anthony Sapienza
Journal:  Case Rep Orthop       Date:  2016-06-06
  3 in total