Literature DB >> 8374707

Full-arch implant framework casting accuracy: preliminary in vitro observation for in vivo testing.

A B Carr1, R B Stewart.   

Abstract

PURPOSE: Conventional techniques for implant metal framework fabrication produce error of a magnitude that is inconsistent with the passive-fit requirement for osseointegrated implants. To understand the correlation between prosthesis fit and the implant-tissue response, evaluation of the interface tissue reactions to customary levels of fit is required. The purpose of this study is to determine the accuracy of torch casting full arch frameworks using a high palladium alloy and a ringless phosphate-bonded investment technique.
MATERIALS AND METHODS: Three different variables were considered relative to casting accuracy effect. The first variable, completeness of mold-fill, compared cast specimens where the entire sprue system was filled as part of the casting and cast specimens without the sprue system filled. The second variable, phosphate-bonded investment special liquid concentrations, compared groups of castings produced from 0%, 12%, 25%, and 50% special liquid. The third variable, investment mold shape, compared casting produced from a conventional ringless mold shape with a modified ringless mold shape where the investment in the same horizontal plane as the pattern was equal in thickness at the internal and external surfaces. Horizontal and vertical distances on the wax pattern and resulting framework were measured using a machinists microscope to determine casting error. Combined vertical and horizontal error was used for comparison between groups (one-way analysis of variance).
RESULTS: No significant differences existed among the three groups compared (P > 0.05). The mean error comparison between the complete and incomplete mold-fill groups showed no statistical difference, while the incomplete fill group was found to be more porous. The mean error of all groups (0.130 mm) exceeded the recommended level of fit needed to satisfy the passive fit requirement by more than 10-fold.
CONCLUSIONS: These results verify clinical observation and suggest that the use of conventional lost wax casting technique to cast one-piece full arch implant frameworks is both imprecise and inaccurate as judged against the passive fit requirement. The consequences of screw-fastening misfitting prostheses to osseointegrated implants is currently under investigation.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8374707     DOI: 10.1111/j.1532-849x.1993.tb00373.x

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  9 in total

1.  Stress Distribution on Various Implant-Retained Bar Overdentures.

Authors:  Övül Kümbüloğlu; Beril Koyuncu; Gözde Yerlioğlu; Nadin Al-Haj Husain; Mutlu Özcan
Journal:  Materials (Basel)       Date:  2022-04-30       Impact factor: 3.748

2.  Accuracy of five implant impression technique: effect of splinting materials and methods.

Authors:  Sang-Jik Lee; Sung-Bum Cho
Journal:  J Adv Prosthodont       Date:  2011-12-28       Impact factor: 1.904

3.  Precision of fit of titanium and cast implant frameworks using a new matching formula.

Authors:  Marianella Sierraalta; Jose L Vivas; Michael E Razzoog; Rui-Feng Wang
Journal:  Int J Dent       Date:  2012-04-08

4.  Three-dimensional accuracy of different correction methods for cast implant bars.

Authors:  Ji-Yung Kwon; Chang-Whe Kim; Young-Jun Lim; Ho-Beom Kwon; Myung-Joo Kim
Journal:  J Adv Prosthodont       Date:  2014-02-14       Impact factor: 1.904

5.  Marginal accuracy of nickel chromium copings fabricated by conventional and accelerated casting procedures, produced with ringless and metal ring investment procedures: A comparative in vitro study.

Authors:  Deepa Alex; Y Bharath Shetty; Glynis Anita Miranda; M Bharath Prabhu; Reshma Karkera
Journal:  J Indian Prosthodont Soc       Date:  2015 Jan-Mar

6.  Fabricating CAD/CAM Implant-Retained Mandibular Bar Overdentures: A Clinical and Technical Overview.

Authors:  Chui Ling Goo; Keson Beng Choon Tan
Journal:  Case Rep Dent       Date:  2017-03-15

7.  Full Arch All-on-4 Fixed Implant-Supported Prostheses with 8.5 Years of Follow-Up: A Case Report.

Authors:  Hakimeh Siadat; Amirreza Rokn; Elaheh Beyabanaki
Journal:  J Dent (Tehran)       Date:  2018-07

8.  Fabrication of a customized impression metal jig for an implant-supported overdenture with a milled bar.

Authors:  Yeganeh Memari; Azadeh Tadayonfard; Amir Fayaz; Elaheh Beyabanaki
Journal:  Dent Res J (Isfahan)       Date:  2021-04-06

9.  Fit of cobalt-chromium implant frameworks before and after ceramic veneering in comparison with CNC-milled titanium frameworks.

Authors:  Per Svanborg; Victoria Stenport; Alf Eliasson
Journal:  Clin Exp Dent Res       Date:  2015-10-26
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.