Literature DB >> 8371920

Ultrasound biomicroscopy in pseudophakic malignant glaucoma.

C Tello1, T Chi, G Shepps, J Liebmann, R Ritch.   

Abstract

BACKGROUND: Malignant glaucoma (ciliary block glaucoma; aqueous misdirection glaucoma) is an incompletely understood, rare and serious complication of intraocular surgery.
METHODS: A woman with pseudophakic malignant glaucoma underwent successful neodymium: YAG (Nd:YAG) laser photodisruption of the anterior hyaloid face with resolution of the glaucoma. High-resolution ultrasound biomicroscopy was used to image the anterior segment and anterior chamber angle before and after laser surgery.
RESULTS: Ultrasound biomicroscopy provided cross-sectional images of the iris, posterior chamber intraocular lens (IOL), and ciliary body and their relative positions before and after resolution of the malignant glaucoma. Anterior rotation of the ciliary body and anterior chamber shallowing normalized after rupture of the anterior hyaloid face.
CONCLUSION: High-resolution ultrasound biomicroscopy provided images consistent with accepted concepts of the pathophysiology of this disease and offers great promise for the future elucidation of the anatomic mechanisms underlying various forms of glaucoma.

Entities:  

Mesh:

Year:  1993        PMID: 8371920     DOI: 10.1016/s0161-6420(93)31479-x

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  22 in total

1.  25-Gauge pars plana vitrectomy for ciliary block (malignant) glaucoma.

Authors:  Li Meng; Wenbin Wei; Yanlong Li; Xiaoying Hui; Xiaodong Han; Xiaobo Shi
Journal:  Int Ophthalmol       Date:  2014-07-26       Impact factor: 2.031

2.  Management of a patient with pseudophakic malignant glaucoma; role of ultrasound biomicroscopy.

Authors:  M Park; K Unigame; J Kiryu; T Kondo
Journal:  Br J Ophthalmol       Date:  1996-07       Impact factor: 4.638

Review 3.  Malignant glaucoma and its management.

Authors:  S Ruben; J Tsai; R A Hitchings
Journal:  Br J Ophthalmol       Date:  1997-02       Impact factor: 4.638

4.  Ultrasound biomicroscopic measurement of anterior chamber angle in premature infants.

Authors:  H Kobayashi; J Kiryu; K Kobayashi; T Kondo
Journal:  Br J Ophthalmol       Date:  1997-06       Impact factor: 4.638

5.  Optical coherence tomography and ultrasound biomicroscopy in the management of pseudophakic malignant glaucoma.

Authors:  Ludwig M Heindl; Konrad R Koch; Claus Cursiefen; Walter Konen
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2013-01-12       Impact factor: 3.117

6.  Ultrasound biomicroscopic measurement of development of anterior chamber angle.

Authors:  H Kobayashi; H Ono; J Kiryu; K Kobayashi; T Kondo
Journal:  Br J Ophthalmol       Date:  1999-05       Impact factor: 4.638

7.  Pilocarpine induces an increase in the anterior chamber angular width in eyes with narrow angles.

Authors:  H Kobayashi; K Kobayashi; J Kiryu; T Kondo
Journal:  Br J Ophthalmol       Date:  1999-05       Impact factor: 4.638

8.  High frequency ultrasound.

Authors:  H R Atta
Journal:  Br J Ophthalmol       Date:  1995-11       Impact factor: 4.638

9.  High frequency ultrasound imaging in pupillary block glaucoma.

Authors:  I M Aslanides; P E Libre; R H Silverman; D Z Reinstein; D R Lazzaro; M J Rondeau; G K Harmon; D J Coleman
Journal:  Br J Ophthalmol       Date:  1995-11       Impact factor: 4.638

10.  Exfoliation syndrome and occludable angles.

Authors:  R Ritch
Journal:  Trans Am Ophthalmol Soc       Date:  1994
View more