Literature DB >> 8370932

Technical influences on immunophenotyping by flow cytometry. The effect of time and temperature of storage on the viability of lymphocyte subsets.

T Ekong1, E Kupek, A Hill, C Clark, A Davies, A Pinching.   

Abstract

The typing of lymphocyte subsets may be influenced by a variety of technical influences including the duration and temperature of sample storage and the method used for staining samples. We have extended a previous study examining the effect of storage conditions on the baseline values of a number of lymphocyte subsets. EDTA-anticoagulated samples from 13 HIV-1-positive and 15 healthy laboratory controls were analyzed for a number of lymphocyte subsets (CD3+, CD4+/CD3+, and CD8+/CD3+ T cells and CD19+ B cells) (whole blood lysis method, Becton-Dickinson FACScan flow cytometer and reagents) at 0, 24, 48, 72, and 96 h after storage at 4 degrees C, 17 degrees C or 21 degrees C. During storage at both 4 degrees C and 21 degrees C, there were significant changes in baseline values of the majority of lymphocyte subsets and some of these were related to the HIV status of the donor. The optimum temperature for storage in our system appeared to be around 17 degrees C in both our study groups. We have also used propidium iodide in order to discriminate between viable and non-viable cells during flow cytometry of lymphocytes from eight HIV-1-positive and five control subjects. The results show that for both HIV-positive and control samples stored at 4 degrees C, and for control subjects at 21 degrees C, the changes in baseline values of lymphocyte subsets observed were not due to selective loss of particular subsets arising from cell death during storage. However, there was substantial loss of cells from all three subsets in HIV-positive subjects during storage at 21 degrees C, with loss of CD8+ and CD3+ T cells being more significant than loss of CD4+ T cells.

Entities:  

Mesh:

Year:  1993        PMID: 8370932     DOI: 10.1016/0022-1759(93)90319-3

Source DB:  PubMed          Journal:  J Immunol Methods        ISSN: 0022-1759            Impact factor:   2.303


  7 in total

Review 1.  Monitoring patients with HIV disease.

Authors:  M Helbert; J Breuer
Journal:  J Clin Pathol       Date:  2000-04       Impact factor: 3.411

2.  Enumeration of lymphocyte subsets using flow cytometry: Effect of storage before and after staining in a developing country setting.

Authors:  Sanju Jalla; Sunil Sazawal; Salkat Deb; Robert E Black; Satya Narayan Das; Archana Sarkar; Maharaj K Bhan
Journal:  Indian J Clin Biochem       Date:  2004-07

3.  Evaluation of the Performance of the Sysmex XT-2000i Hematology Analyzer With Whole Bloods Stored at Room Temperature.

Authors:  Valerie L Hill; Virginia Z Simpson; Jeanette M Higgins; Zonghui Hu; Randy A Stevens; Julie A Metcalf; Michael Baseler
Journal:  Lab Med       Date:  2009-12

4.  Maturational changes in peripheral lymphocyte subsets pertinent to monitoring human immunodeficiency virus-infected Chinese pediatric patients.

Authors:  K M Kam; W L Leung; K H Wong; S S Lee; M Y Hung; M Y Kwok
Journal:  Clin Diagn Lab Immunol       Date:  2001-09

5.  Impact of blood processing variations on natural killer cell frequency, activation, chemokine receptor expression and function.

Authors:  Vivek Naranbhai; Pat Bartman; Dudu Ndlovu; Pamela Ramkalawon; Thumbi Ndung'u; Douglas Wilson; Marcus Altfeld; William H Carr
Journal:  J Immunol Methods       Date:  2011-01-19       Impact factor: 2.303

6.  Lymphocyte subpopulation reference ranges for monitoring human immunodeficiency virus-infected Chinese adults.

Authors:  K M Kam; W L Leung; M Y Kwok; M Y Hung; S S Lee; W P Mak
Journal:  Clin Diagn Lab Immunol       Date:  1996-05

7.  CD3-positive B cells: a storage-dependent phenomenon.

Authors:  Angela Nagel; Christian Möbs; Hartmann Raifer; Heinz Wiendl; Michael Hertl; Rüdiger Eming
Journal:  PLoS One       Date:  2014-10-16       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.