Literature DB >> 8370610

A new model to test platelet adhesion under dynamic conditions. Application to the evaluation of a titanium nitride coating.

I Dion1, C Baquey, P Havlik, J R Monties.   

Abstract

In order to evaluate under dynamic circumstances the in vitro platelet adhesion induced by rigid materials such as ceramic coatings deposited on selected substrates, a new model simulating a tube has been designed. In vitro platelet adhesion was assessed with this new model: the material was titanium nitride (TiN) deposited on Ti6A14V (TA6V) titanium alloy by a physical vapor deposition (PVD) process. The results were compared to those obtained with complete titanium carbide (TiC) graphite tubes coated with TiN by a chemical vapor deposition (CVD) process. The difference observed (less than 25%) in favour of the new system, could be due to the better surface state of the construction materials of this system. In fact it is a systemic error. However TiN confirms its good performance as a blood-contacting biomaterial.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8370610

Source DB:  PubMed          Journal:  Int J Artif Organs        ISSN: 0391-3988            Impact factor:   1.595


  4 in total

1.  Surface modification of titanium substrate with a novel covalently-bound copolymer thin film for improving its platelet compatibility.

Authors:  Ching-Hsiung Shen; Yu-Jen Cho; Yi-Ching Lin; Li-Chin Chien; Tzer-Min Lee; Wen-Hsi Chuang; Jui-Che Lin
Journal:  J Mater Sci Mater Med       Date:  2015-01-29       Impact factor: 3.896

2.  Gentamicin-loaded wound dressing with polyvinyl alcohol/dextran hydrogel: gel characterization and in vivo healing evaluation.

Authors:  Ma-Ro Hwang; Jong Oh Kim; Jeong Hoon Lee; Yong Il Kim; Jeong Hoon Kim; Sun Woo Chang; Sung Gju Jin; Jung Ae Kim; Won Seok Lyoo; Sung Soo Han; Sae Kwang Ku; Chul Soon Yong; Han-Gon Choi
Journal:  AAPS PharmSciTech       Date:  2010-07-07       Impact factor: 3.246

3.  Bone response to surface-modified titanium implants: studies on the early tissue response to implants with different surface characteristics.

Authors:  C Larsson Wexell; P Thomsen; B-O Aronsson; P Tengvall; M Rodahl; J Lausmaa; B Kasemo; L E Ericson
Journal:  Int J Biomater       Date:  2013-09-23

4.  Study of locust bean gum reinforced cyst-chitosan and oxidized dextran based semi-IPN cryogel dressing for hemostatic application.

Authors:  Lalit Kumar Meena; Pavani Raval; Dhaval Kedaria; Rajesh Vasita
Journal:  Bioact Mater       Date:  2017-12-08
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.