Literature DB >> 8366735

[Measuring impedance for evaluating ischemia damage to the human liver in preparation for transplantation].

J Erhard1, R Lange, E Gersing, R Scherer, M M Gebhard, P Sanchez, H J Bretschneider, F W Eigler.   

Abstract

In 22 human donor livers the measurement of the non-invasive bioelectrical impedance was performed prospectively to evaluate the degree of tissue damage sustained during cold ischemia. The results of the measurement were correlated with liver function, the method of organ preservation and the period of ischemia. The impedance was measured in vivo as 620 ohm (at 192 Hz), the phase angle as -7.4 degrees (at 5 kHz). The results were compared with the data obtained from 72 patients who underwent elective laparotomies. The 22 donor livers were studied further during ischemia. The method was found to be a reliable way of detecting severe damage to the hepatocytes during the cold ischemia.

Entities:  

Mesh:

Year:  1993        PMID: 8366735     DOI: 10.1007/bf00184365

Source DB:  PubMed          Journal:  Langenbecks Arch Chir        ISSN: 0023-8236


  9 in total

1.  [Measuring electrical impedance of organs--instrumental equipment for research and clinical use].

Authors:  E Gersing
Journal:  Biomed Tech (Berl)       Date:  1991 Jan-Feb       Impact factor: 1.411

2.  [Measuring electric impedance of organs--methodologic principles].

Authors:  E Gersing; F Bach; C Brockhoff; M M Gebhard; G Kehrer; A Meissner; H J Bretschneider
Journal:  Biomed Tech (Berl)       Date:  1991-04       Impact factor: 1.411

3.  Biochemical multisensor element for estimation of organ viability.

Authors:  P G Fenzlein; D Abendroth; M Schilling; M Schaidt; W Land
Journal:  Transplant Proc       Date:  1991-02       Impact factor: 1.066

4.  [Comparative studies of impedance measurement of the orthotopically transplanted liver (author's transl)].

Authors:  B Rigler; G Lanner; W Hermann; W Stenzl
Journal:  Langenbecks Arch Chir       Date:  1974

5.  [Tissular impedance. Determination of the viability of the kidney preserved in hypothermia].

Authors:  C Fourcade; M Barbier; P Perrin; E Chignier de Alcantara
Journal:  Nouv Presse Med       Date:  1973-03-31

6.  [Value of dielectricity constants as a vitality test].

Authors:  B Seemann; R Templin; R Bast; B Hudemann; R John; U Schmidt; T Erdmann
Journal:  Z Urol Nephrol       Date:  1983-09

7.  On-line detection of reversible myocardial ischemic injury by measurement of myocardial electrical impedance.

Authors:  M I Ellenby; K W Small; R M Wells; D J Hoyt; J E Lowe
Journal:  Ann Thorac Surg       Date:  1987-12       Impact factor: 4.330

8.  [Liver function tests in a clinical comparison].

Authors:  W Stremmel; R Wojdat; R Groteguth; M Zoedler; T Ebener; C Niederau; H Becker; G Strohmeyer
Journal:  Z Gastroenterol       Date:  1992-11       Impact factor: 2.000

9.  Impedance spectroscopy: a method for surveillance of ischemia tolerance of the heart.

Authors:  M M Gebhard; E Gersing; C J Brockhoff; P A Schnabel; H J Bretschneider
Journal:  Thorac Cardiovasc Surg       Date:  1987-02       Impact factor: 1.827

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.