Literature DB >> 8355334

Imaging of the vertebrobasilar system by transcranial color-coded real-time sonography.

G Becker, A Lindner, U Bogdahn.   

Abstract

The vertebrobasilar system was investigated in 75 persons by TCCS to evaluate the applicability and diagnostic capacity of this transcranial Duplex technique. Transforaminal and transtemporal acoustic windows were employed to identify the vertebral arteries, basilar artery (PCA) and major branches of the vertebrobasilar system. The frequency of identifying the basilar artery and the PCA ranged from 84 to 94% but was poor for the distal segment of the basilar artery (45.3%). The origin of the basilar artery was disclosed by transcranial Duplex sonography at an average depth of 7.0 cm (range 6.0 to 8.0 cm). The assignment of the obtained flow signals to specific vascular segments was improved by this new technique. In addition, four persons received a maximum of six intravenous injections of a transpulmonary stable sonographic contrast agent (SHU 508 A) to enhance Doppler signal intensity derived from the vertebrobasilar system. The vascular trunk and all major branches of the vertebrobasilar system were identified in these four persons. We conclude that TCCS of the vertebrobasilar system will improve reliability of transcranial sonographic examination.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8355334     DOI: 10.7863/jum.1993.12.7.395

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  5 in total

1.  Vertebrobasilar transcranial color-coded duplex ultrasonography: improvement with echo enhancement.

Authors:  Erwin Stolz; Martin Nückel; Irene Mendes; Tibo Gerriets; Manfred Kaps
Journal:  AJNR Am J Neuroradiol       Date:  2002 Jun-Jul       Impact factor: 3.825

2.  Echo-enhanced transcranial color-coded duplex sonography in the diagnosis of cerebrovascular events: a validation study.

Authors:  A Kunz; G Hahn; D Mucha; A Müller; K M Barrett; R von Kummer; G Gahn
Journal:  AJNR Am J Neuroradiol       Date:  2006 Nov-Dec       Impact factor: 3.825

3.  Visualisation of intracranial aneurysms by transcranial duplex sonography.

Authors:  C Klötzsch; H C Nahser; B Fischer; H Henkes; D Kühne; P Berlit
Journal:  Neuroradiology       Date:  1996-08       Impact factor: 2.804

4.  Cerebral Ventricular Dimensions After Decompressive Craniectomy: A Comparison Between Bedside Sonographic Duplex Technique and Cranial Computed Tomography.

Authors:  Habib Bendella; Marc Maegele; Alexander Hartmann; Joachim Spreer; Nadine Rommel; Rolf Lefering; Makoto Nakamura; Alhadi Igressa
Journal:  Neurocrit Care       Date:  2017-06       Impact factor: 3.210

5.  Real-time cerebral angiography: sensitivity of a new contrast-specific ultrasound technique.

Authors:  T Hölscher; J A Sattin; R Raman; W Wilkening; C V Fanale; S E Olson; R F Mattrey; P D Lyden
Journal:  AJNR Am J Neuroradiol       Date:  2007-04       Impact factor: 3.825

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.