Literature DB >> 8352024

An indifference point for electrical impedance in humans.

G Perko1, G Payne, N H Secher.   

Abstract

Regional electrical impedance was used over eight sections of the human body (two thoracic; one abdominal; two thigh; two around the knee; and one lower leg) to determine the volume indifference point during passive head-up tilt in eight subjects. Head-up tilt was performed in 10 degrees increments from 0 degree to 60 degrees over 6 min. Electrical impedance increased over the thorax in proportion to the head-up tilt angle, while abdominal impedance did not change significantly, and over the thigh and the lower leg it decreased with increasing head-up tilt angle. No change in electrical impedance was noted just above the knee, and electrical impedance just below the knee decreased only marginally. Results demonstrate minimal fluid accumulation around the knee during head-up tilt. Furthermore, in humans the electrical impedance and therefore probably the volume indifference point is positioned between the umbilicus and crista iliaca.

Entities:  

Mesh:

Year:  1993        PMID: 8352024     DOI: 10.1111/j.1748-1716.1993.tb09541.x

Source DB:  PubMed          Journal:  Acta Physiol Scand        ISSN: 0001-6772


  8 in total

Review 1.  Gravity, the hydrostatic indifference concept and the cardiovascular system.

Authors:  Helmut Hinghofer-Szalkay
Journal:  Eur J Appl Physiol       Date:  2010-09-21       Impact factor: 3.078

2.  Effects of passive heating on central blood volume and ventricular dimensions in humans.

Authors:  C G Crandall; T E Wilson; J Marving; T W Vogelsang; A Kjaer; B Hesse; N H Secher
Journal:  J Physiol       Date:  2007-10-25       Impact factor: 5.182

3.  Heart rate and stroke volume response patterns to augmented orthostatic stress.

Authors:  Nandu Goswami; Andreas Roessler; Helmut K Lackner; Daniel Schneditz; Erik Grasser; Helmut G Hinghofer-Szalkay
Journal:  Clin Auton Res       Date:  2009-03-07       Impact factor: 4.435

4.  Identification of the human electrical impedance indifferent point: a surrogate for the volume indifferent point?

Authors:  Sara S Jarvis; James A Pawelczyk
Journal:  Eur J Appl Physiol       Date:  2009-08-12       Impact factor: 3.078

5.  Pharmacological manipulation of cardiovascular responses to lower body negative pressure.

Authors:  G Perko; J F Schmidt; J Warberg; N H Secher
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1996

6.  The venous pump does not affect the indifference point for electrical impedance in humans.

Authors:  G Perko; R Tilgreen; N H Secher
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1995

7.  Influence of head-up tile and lower body negative pressure on the internal jugular vein.

Authors:  Shigehiko Ogoh; Ai Hirasawa; Shigeki Shibata
Journal:  Physiol Rep       Date:  2022-05

8.  The location of the human volume indifferent point predicts orthostatic tolerance.

Authors:  Sara S Jarvis; James A Pawelczyk
Journal:  Eur J Appl Physiol       Date:  2010-01-26       Impact factor: 3.078

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.