Literature DB >> 8350729

K-space substitution: a novel dynamic imaging technique.

R A Jones1, O Haraldseth, T B Müller, P A Rinck, A N Oksendal.   

Abstract

A rapid dynamic imaging sequence has been developed in which only the 32 phase encoding steps that encode low spatial frequencies are collected for each dynamic image. These are substituted into a previously acquired, 128 x 128 raw data set prior to image reconstruction. In this way the dynamic information is retained while the overall appearance is improved in comparison with images obtained by zero filling to 128 x 128, leading to better qualitative evaluation. The limited k-space sampling means that the technique is most effective for large homogeneous areas of signal change since fine changes in contrast are imperfectly recorded.

Mesh:

Substances:

Year:  1993        PMID: 8350729     DOI: 10.1002/mrm.1910290618

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  33 in total

1.  Increasing temporal resolution of DSC perfusion MRI using the analytic image concept.

Authors:  Josiane Yankam Njiwa; David Ratering; Christof Baltes; Markus Rudin
Journal:  MAGMA       Date:  2010-08-07       Impact factor: 2.310

2.  Noninvasive evaluation of cerebral arteriovenous malformations by 4D-MRA for preoperative planning and postoperative follow-up in 56 patients: comparison with DSA and intraoperative findings.

Authors:  D R Hadizadeh; G M Kukuk; D T Steck; J Gieseke; H Urbach; H J Tschampa; S Greschus; A Kovàcs; M Möhlenbruch; A Bostroem; H H Schild; W A Willinek
Journal:  AJNR Am J Neuroradiol       Date:  2012-02-02       Impact factor: 3.825

Review 3.  Ultrafast inverse imaging techniques for fMRI.

Authors:  Fa-Hsuan Lin; Kevin W K Tsai; Ying-Hua Chu; Thomas Witzel; Aapo Nummenmaa; Tommi Raij; Jyrki Ahveninen; Wen-Jui Kuo; John W Belliveau
Journal:  Neuroimage       Date:  2012-01-21       Impact factor: 6.556

4.  Fast, limited-data photoacoustic imaging for multiplexed systems using a frequency-domain estimation technique.

Authors:  John K Gamelin; Andres Aguirre; Quing Zhu
Journal:  Med Phys       Date:  2011-03       Impact factor: 4.071

5.  Simulation study of the effect of golden-angle KWIC with generalized kinetic model analysis on diagnostic accuracy for lesion discrimination.

Authors:  Melanie Freed; Sungheon G Kim
Journal:  Magn Reson Imaging       Date:  2014-09-28       Impact factor: 2.546

6.  Correlation imaging for multiscan MRI with parallel data acquisition.

Authors:  Yu Li; Charles Dumoulin
Journal:  Magn Reson Med       Date:  2012-02-28       Impact factor: 4.668

7.  Three-dimensional through-time radial GRAPPA for renal MR angiography.

Authors:  Katherine L Wright; Gregory R Lee; Philipp Ehses; Mark A Griswold; Vikas Gulani; Nicole Seiberlich
Journal:  J Magn Reson Imaging       Date:  2014-01-21       Impact factor: 4.813

Review 8.  Multiparametric MR Imaging in Abdominal Malignancies.

Authors:  Antonio Luna; Shivani Pahwa; Claudio Bonini; Lidia Alcalá-Mata; Katherine L Wright; Vikas Gulani
Journal:  Magn Reson Imaging Clin N Am       Date:  2016-02       Impact factor: 2.266

9.  Three-dimensional imaging of ventilation dynamics in asthmatics using multiecho projection acquisition with constrained reconstruction.

Authors:  James H Holmes; Rafael L O'Halloran; Ethan K Brodsky; Thorsten A Bley; Christopher J Francois; Julia V Velikina; Ronald L Sorkness; William W Busse; Sean B Fain
Journal:  Magn Reson Med       Date:  2009-12       Impact factor: 4.668

10.  Linear constraint minimum variance beamformer functional magnetic resonance inverse imaging.

Authors:  Fa-Hsuan Lin; Thomas Witzel; Thomas A Zeffiro; John W Belliveau
Journal:  Neuroimage       Date:  2008-07-11       Impact factor: 6.556

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.