Literature DB >> 8346496

Use of a combined oxygen and carbon dioxide transcutaneous electrode in the estimation of gas exchange during exercise.

M K Sridhar1, R Carter, F Moran, S W Banham.   

Abstract

BACKGROUND: Accurate and reliable measurement of gas exchange during exercise has traditionally involved arterial cannulation. Non-invasive devices to estimate arterial oxygen (O2) and carbon dioxide (CO2) tensions are now available. A method has been devised and evaluated for measuring gas exchange during exercise with a combined transcutaneous O2 and CO2 electrode.
METHODS: Symptom limited exercise tests were carried out in 24 patients reporting effort intolerance and breathlessness. Exercise testing was performed by bicycle ergometry with a specifically designed protocol involving gradual two minute workload increments. Arterial O2 and CO2 tensions were measured at rest and during exercise by direct blood sampling from an indwelling arterial cannula and a combined transcutaneous electrode heated to 45 degrees C. The transcutaneous system was calibrated against values obtained by direct arterial sampling before each test.
RESULTS: In all tests the trend of gas exchange measured by the transcutaneous system was true to the trend measured from direct arterial sampling. In the 140 measurements the mean difference between the O2 tensions estimated by direct sampling and the transcutaneous method was 0.08 kPa (0.62 mm Hg, limits of agreement 4.42 and -3.38 mm Hg). The mean difference between the methods for CO2 was 0.02 kPa (0.22 mm Hg, limits of agreement 2.20 and -1.70 mm Hg). There was no morbidity associated with the use of the transcutaneous electrode heated to 45 degrees C.
CONCLUSIONS: A combined transcutaneous O2 and CO2 electrode heated to 45 degrees C can be used to provide a reliable estimate of gas exchange during gradual incremental exercise in adults.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8346496      PMCID: PMC464594          DOI: 10.1136/thx.48.6.643

Source DB:  PubMed          Journal:  Thorax        ISSN: 0040-6376            Impact factor:   9.139


  9 in total

1.  Electrodes for blood pO2 and pCO2 determination.

Authors:  J W SEVERINGHAUS; A F BRADLEY
Journal:  J Appl Physiol       Date:  1958-11       Impact factor: 3.531

Review 2.  Noninvasive assessment of blood gases.

Authors:  J S Clark; B Votteri; R L Ariagno; P Cheung; J H Eichhorn; R J Fallat; S E Lee; C J Newth; H Rotman; D Y Sue
Journal:  Am Rev Respir Dis       Date:  1992-01

3.  Complications of percutaneous radial-artery cannulation: an objective prospective study in man.

Authors:  R F Bedford; H Wollman
Journal:  Anesthesiology       Date:  1973-03       Impact factor: 7.892

4.  Terminal dehydration.

Authors: 
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

5.  Comparison of arterial-end-tidal PCO2 difference and dead space/tidal volume ratio in respiratory failure.

Authors:  M K Yamanaka; D Y Sue
Journal:  Chest       Date:  1987-11       Impact factor: 9.410

Review 6.  Cardiopulmonary exercise testing.

Authors:  R S McKelvie; N L Jones
Journal:  Clin Chest Med       Date:  1989-06       Impact factor: 2.878

7.  Evaluation of a single transcutaneous PO2-PCO2 sensor in adult patients.

Authors:  C K Mahutte; T M Michiels; K T Hassell; D M Trueblood
Journal:  Crit Care Med       Date:  1984-12       Impact factor: 7.598

8.  Changes in transcutaneous oxygen tension during exercise in pulmonary emphysema.

Authors:  J A Hughes; B J Gray; D C Hutchison
Journal:  Thorax       Date:  1984-06       Impact factor: 9.139

Review 9.  Blood/gas equilibrium of carbon dioxide in lungs. A critical review.

Authors:  P Scheid; J Piiper
Journal:  Respir Physiol       Date:  1980-01
  9 in total
  3 in total

Review 1.  Guideline-oriented perioperative management of patients with bronchial asthma and chronic obstructive pulmonary disease.

Authors:  Michiaki Yamakage; Sohshi Iwasaki; Akiyoshi Namiki
Journal:  J Anesth       Date:  2008-11-15       Impact factor: 2.078

2.  Resting Dead Space Fraction as Related to Clinical Characteristics, Lung Function, and Gas Exchange in Male Patients with Chronic Obstructive Pulmonary Disease.

Authors:  Ming-Lung Chuang; Benjamin Yung-Thing Hsieh; I-Feng Lin
Journal:  Int J Gen Med       Date:  2021-02-03

3.  Physiologic and other effects and compliance with long-term respirator use among medical intensive care unit nurses.

Authors:  Terri Rebmann; Ruth Carrico; Jing Wang
Journal:  Am J Infect Control       Date:  2013-06-12       Impact factor: 2.918

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.