Literature DB >> 8343241

Size of endotracheal tube and neonatal acquired subglottic stenosis. Study Group for Neonatology and Pediatric Emergencies in the Parisian Area.

P Contencin1, P Narcy.   

Abstract

OBJECTIVE: Risk factors for acquired laryngotracheal stenosis in newborn infants are poorly known. The extreme scarcity of acquired laryngotracheal stenosis in young infants in France, compared with the published rate in the English literature, suggested that these patients may be treated in a different way in France. A prospective study was performed to analyze local features.
DESIGN: Six-month multicenter inception cohort study.
SETTING: Seven neonatal intensive care units of referral centers in the area of Paris, France. PATIENTS: A total of 247 intubated surviving neonates in a consecutive sample during 6 months. INTERVENTION: A file was completed with sex, birth weight, gestational age, underlying disease, and every feature concerning the intubation period and the outcome. MAIN OUTCOME MEASURES: All the collected data were compared with those available from previous studies in the English literature.
RESULTS: After extubation, respiratory outcome was uncomplicated in 242 cases. The five patients with dyspnea were treated medically and recovered. A much higher rate of extubation difficulties was reported in the English literature. The rate of stenosis in this series was significantly lower than in previously reported studies. The differences between this and other series seem to be higher birth weights, shorter duration of intubation, and, most important, a smaller tube size (2.5 mm in neonates weighing less than 2500 g and 3.0 mm in those weighing 2500 g or more).
CONCLUSIONS: Although this is a limited series and many unknown variables can differ from those in previous studies, the size of the endotracheal tube appears to be a major risk factor for acquired laryngotracheal stenosis in the neonate. Further studies seem necessary to point out additional factors.

Entities:  

Mesh:

Year:  1993        PMID: 8343241     DOI: 10.1001/archotol.1993.01880200015002

Source DB:  PubMed          Journal:  Arch Otolaryngol Head Neck Surg        ISSN: 0886-4470


  12 in total

1.  Dysphonia at 12 months corrected age in very low-birth-weight-born children.

Authors:  Lars Garten; Angela Salm; Jochen Rosenfeld; Elisabeth Walch; Christoph Bührer; Dieter Hüseman
Journal:  Eur J Pediatr       Date:  2010-10-07       Impact factor: 3.183

2.  Voice related quality of life in pediatric patients with a history of prematurity.

Authors:  Patrick C Walz; Michael P Hubbell; Charles A Elmaraghy
Journal:  Int J Pediatr Otorhinolaryngol       Date:  2014-03-28       Impact factor: 1.675

3.  Role of Topical Medication in Prevention of Post-extubation Subglottic Stenosis.

Authors:  Saravanam Prasanna Kumar; Arunachalam Ravikumar; Johnson Thanka
Journal:  Indian J Otolaryngol Head Neck Surg       Date:  2017-01-17

4.  Acquired subglottic stenosis caused by methicillin resistant Staphylococcus aureus that produce epidermal cell differentiation inhibitor.

Authors:  Y Yamada; M Sugai; M Woo; N Nishida; T Sugimoto
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2001-01       Impact factor: 5.747

Review 5.  Cuffed versus uncuffed endotracheal tubes for neonates.

Authors:  Vedanta Dariya; Luca Moresco; Matteo Bruschettini; Luc P Brion
Journal:  Cochrane Database Syst Rev       Date:  2022-01-24

6.  Anesthesia for subglottic stenosis in pediatrics.

Authors:  Essam A Eid
Journal:  Saudi J Anaesth       Date:  2009-07

7.  Real-time subglottic stenosis imaging using optical coherence tomography in the rabbit.

Authors:  Jennifer L Lin; Amy Y Yau; Jonathon Boyd; Ashley Hamamoto; Erica Su; Lauren Tracy; Lauren Tracey; Andrew E Heidari; Alex H Wang; Gurpreet Ahuja; Zhongping Chen; Brian J Wong
Journal:  JAMA Otolaryngol Head Neck Surg       Date:  2013-05       Impact factor: 6.223

8.  Laryngeal stenosis among hospitalized children: Results from a nationwide cross-sectional survey.

Authors:  Romaine F Johnson; Amal Isaiah
Journal:  Laryngoscope Investig Otolaryngol       Date:  2018-04-16

Review 9.  Current methodological and technical limitations of time and volumetric capnography in newborns.

Authors:  Gerd Schmalisch
Journal:  Biomed Eng Online       Date:  2016-08-30       Impact factor: 2.819

10.  Effect of tidal volume and end tracheal tube leakage on end-tidal CO2 in very low birth weight infants.

Authors:  Daijiro Takahashi; Koko Goto; Kei Goto
Journal:  J Perinatol       Date:  2020-08-04       Impact factor: 2.521

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.