Column agglutination technology: the antiglobulin test.

K J Reis1, R Chachowski, A Cupido, D Davies, J Jakway, T M Setcavage.   

Abstract

A new system for typing and screening blood, based on the sieving effect of glass bead microparticles, has been developed. The test is performed in a microcolumn in which the red cell agglutinates are trapped in the glass bead matrix during centrifugation, and unagglutinated cells form a pellet at the bottom of the column. Anti-human globulin reagents were incorporated in the diluent and the new test system, column agglutination technology, was compared to conventional tube tests and low-ionic-strength method. Sera and plasmas (228 samples) were screened for red cell antibodies with two anti-human globulin reagents: one containing only anti-IgG and the other containing both anti-IgG and anti-C3b, -C3d. After initial testing, there was 94-percent agreement between column agglutination technology and tube tests, and after repeat testing, there was 97-percent agreement. The column agglutination technology anti-human globulin test eliminates the need to wash red cells, which decreases the overall test time. The test is easy to perform, and the results are more objective than those with tube and microplate methods.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8342229     DOI: 10.1046/j.1537-2995.1993.33893342744.x

Source DB:  PubMed          Journal:  Transfusion        ISSN: 0041-1132            Impact factor:   3.157


  4 in total

1.  Comparison of conventional tube test technique and gel microcolumn assay for direct antiglobulin test: a large study.

Authors:  M C Z Novaretti; E Jens; T Pagliarini; S L Bonifacio; P E Dorlhiac-Llacer; D A F Chamone
Journal:  J Clin Lab Anal       Date:  2004       Impact factor: 2.352

2.  Use of gel microcolumn assay for the detection of drug-induced positive direct antiglobulin tests.

Authors:  M C Z Novaretti; C R Sopeleti; P E Dorlhiac-Llacer; D A F Chamone
Journal:  J Clin Lab Anal       Date:  2005       Impact factor: 2.352

3.  Comparison of micro column technology with conventional tube methods for antibody detection.

Authors:  Sachin Garg; Nishant Saini; Ravneet Kaur Bedi; Sabita Basu
Journal:  J Lab Physicians       Date:  2017 Apr-Jun

4.  Comparison of two column agglutination tests for red blood cell antibody testing.

Authors:  Jonas Sawierucha; Marion Posset; Viola Hähnel; Christian L Johnson; James A Hutchinson; Norbert Ahrens
Journal:  PLoS One       Date:  2018-12-31       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.