Literature DB >> 8341069

Experience with four surgical techniques to repair traumatic aortic pseudoaneurysm.

J T Walls1, T M Boley, J J Curtis, R A Schmaltz.   

Abstract

We report our experience with 27 (22 male and 5 female) patients who were from 16 to 82 years of age (median 29 years) who underwent surgical repair for traumatic pseudoaneurysm of the thoracic aorta. The cause of injury in all cases was blunt trauma. Repair was accomplished with partial bypass by means of a roller pump with systemic heparinization in 6 (23%), Gott shunt in 7 (27%), clamp-and-sew technique in 6 (23%), and centrifugal pump without systemic heparinization in 8 (30%). Significant postoperative complications occurred in 12 patients. Paraplegia occurred in 1 patient (clamp and sew), anterior spinal cord syndrome in 1 (clamp and sew), renal failure in 1 (Gott shunt), temporary vocal cord paralysis in 2 (Gott shunt, centrifugal pump), permanent vocal cord paralysis in 1 (roller pump), and coagulopathy in 2 (centrifugal pump, Gott shunt). Hospital mortality occurred in 5 of 27 (19%), (1 clamp and sew, 1 Gott shunt, 1 centrifugal pump, 2 roller pump). Follow-up of survivors (1 week to 20 years, median 2.1 years) revealed no further problems from either aortic graft or primary repair. Although patient numbers are small, evaluation of each of the four surgical techniques leads us to favor repair with shunting with a centrifugal pump without heparin. The potential advantage of left atrial-left femoral artery shunt with centrifugal pump support was evident in operative field exposure, afterload reduction, avoidance of clamp injury, and maintenance of stable distal aortic perfusion without heparin.

Entities:  

Mesh:

Year:  1993        PMID: 8341069

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  2 in total

1.  Comparison of spinal cord protection utilizing left atrial-femoral with femoral-femoral bypass in patients with traumatic rupture of the aortic isthmus.

Authors:  Darryl S Weiman; A Tayfun Gurbuz; Andrei Gursky; Ganpat Valaulikar; James W Pate
Journal:  World J Surg       Date:  2006-09       Impact factor: 3.352

2.  Recent clinical experience with left heart bypass using a centrifugal pump for repair of traumatic aortic transection.

Authors:  M F Szwerc; D H Benckart; J C Lin; C G Johnnides; J A Magovern; G J Magovern; G J Magovern
Journal:  Ann Surg       Date:  1999-10       Impact factor: 12.969

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.