Blood recirculation in intravenous catheters for hemodialysis.

Z J Twardowski1, J C Van Stone, M E Jones, M E Klusmeyer, J D Haynie.   

Abstract

Long-term i.v. catheters for hemodialysis have the outflow tip extending approximately 2 to 3 cm beyond the inflow tip to prevent blood recirculation during dialysis; however, the lumens are frequently reversed because of inflow failure (i.e., inadequate flow when the inflow lumen is used for blood inflow into the dialyzer). Blood recirculation with reversed lumens (outflow lumen used for blood inflow) in inflow failure catheters and with standard and reversed lumens in well-functioning catheters was measured. Recirculation was measured at a blood flow of 300 mL/min. Systemic blood samples were taken after blood flow was slowed to 50 mL/min. Blood recirculation was calculated as a percentage of the difference between systemic and inflow lumen solute concentrations divided by the difference between systemic and outflow lumen solute concentrations. For each catheter, the recirculation values were calculated separately for urea and creatinine. Average recirculation as measured by both solutes was also calculated. Blood recirculations with standard lumens of well-functioning catheters, reversed lumens of well-functioning catheters, and reversed lumens of inflow failure catheters were 2.09 +/- 1.95, 13.58 +/- 9.87, and 7.10 +/- 5.12 (mean +/- SD), respectively. Whereas recirculation with standard lumens of well-functioning catheters is negligible, reversal of lumens causes considerable recirculation. Recirculation in inflow failure catheters with reversed lumens is significantly less than that with reversed lumens of well-functioning catheters. It was proposed that a blood clot attached at and/or immediately distal to the inflow lumen may disperse outflowing blood and diminish recirculation in inflow failure catheters.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1993        PMID: 8338931     DOI: 10.1681/ASN.V3121978

Source DB:  PubMed          Journal:  J Am Soc Nephrol        ISSN: 1046-6673            Impact factor:   10.121


  1 in total

1.  Improvement of hemodialysis catheter function with tenecteplase: a phase III, open-label study: TROPICS 4.

Authors:  Steven Fishbane; Samuel L Milligan; Kenneth D Lempert; Joachim E W Hertel; James B Wetmore; Matthew J Oliver; Martha Blaney; Barbara S Gillespie; Joan R Jacobs; Susan M Begelman
Journal:  J Thromb Thrombolysis       Date:  2011-01       Impact factor: 2.300

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.