Triple-frequency method for measuring blood impedance.

T X Zhao1, B Jacobson, T Ribbe.   

Abstract

A method was developed for simultaneously measuring plasma resistance, cell interior resistance and cell membrane capacitance of blood. A three-element circuit model for simulating the impedance of blood was evaluated by comparing measured and calculated impedance frequency curves and was found feasible. The values of the three elements of the model could be determined by measuring the impedance amplitudes at three different frequencies. The cell membrane capacitance (Cm) was independent of temperature in the range 25-40 degrees C and was significantly higher for blood with ethylenediaminetetraacetic acid (EDTA) as anticoagulant than that for blood with sodium citrate and acid citrate dextrose (ACD). The Cm value of blood from patients with high erythrocyte sedimentation rate (ESR) was found to be significantly higher than that of blood from patients with low ESR. This suggests that the membrane capacitance might be a potential parameter for clinical applications.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8334410     DOI: 10.1088/0967-3334/14/2/006

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  6 in total

1.  Physiological quality assessment of stored whole blood by means of electrical measurements.

Authors:  Y Ulgen; M Sezdi
Journal:  Med Biol Eng Comput       Date:  2007-06-28       Impact factor: 2.602

2.  Quantitative correlations among fibrinogen concentration, sedimentation rate and electrical impedance of blood.

Authors:  T X Zhao; B Jacobson
Journal:  Med Biol Eng Comput       Date:  1997-05       Impact factor: 2.602

3.  Dielectric properties of human blood and erythrocytes at radio frequencies (0.2-10 MHz); dependence on cell volume fraction and medium composition.

Authors:  H Beving; L E Eriksson; C L Davey; D B Kell
Journal:  Eur Biophys J       Date:  1994       Impact factor: 1.733

4.  Antibody-functionalized aluminum oxide-coated particles targeting neutrophil receptors in a multifrequency microfluidic impedance cytometer.

Authors:  Brandon K Ashley; Jianye Sui; Mehdi Javanmard; Umer Hassan
Journal:  Lab Chip       Date:  2022-08-09       Impact factor: 7.517

5.  Design and Utility of a Point-of-Care Microfluidic Platform to Assess Hematocrit and Blood Coagulation.

Authors:  Jevgenia Zilberman-Rudenko; Rachel M White; Dmitriy A Zilberman; Hari H S Lakshmanan; Rachel A Rigg; Joseph J Shatzel; Jeevan Maddala; Owen J T McCarty
Journal:  Cell Mol Bioeng       Date:  2018-07-19       Impact factor: 2.321

6.  Real-time electrical impedimetric monitoring of blood coagulation process under temperature and hematocrit variations conducted in a microfluidic chip.

Authors:  Kin Fong Lei; Kuan-Hao Chen; Po-Hsiang Tsui; Ngan-Ming Tsang
Journal:  PLoS One       Date:  2013-10-07       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.