Literature DB >> 8331997

Simulation of time-resolved breast transillumination.

E B de Haller1, C Depeursinge.   

Abstract

A Monte Carlo simulation has been developed to predict the quality of time-resolved images of the breast by transillumination. The smallest diameter of a detectable carcinoma located in the breast has been computed. The simulation suggests that time-resolved imaging of the breast is possible and invaluable in the near infra-red (NIR) by transillumination. The enhancement of the transfer function by the introduction of time-resolved detection is limited by the contribution of noise at short integration times. The estimated diameter of the smallest detectable sphere is derived from the image quality index (IQI) theory and its value is around 4 mm. The simulated images of an absorbing sphere (approximating the carcinoma) within a homogeneous medium (approximating the surrounding tissue) show a significant improvement of the image with short integration time.

Entities:  

Mesh:

Year:  1993        PMID: 8331997     DOI: 10.1007/bf02446675

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  18 in total

1.  Optical properties of normal and diseased human breast tissues in the visible and near infrared.

Authors:  V G Peters; D R Wyman; M S Patterson; G L Frank
Journal:  Phys Med Biol       Date:  1990-09       Impact factor: 3.609

2.  Transillumination imaging performance: a time-of-flight imaging system.

Authors:  J C Hebden; R A Kruger
Journal:  Med Phys       Date:  1990 May-Jun       Impact factor: 4.071

3.  Light scanning of nonpalpable breast lesions: reevaluation.

Authors:  B Monsees; J M Destouet; D Gersell
Journal:  Radiology       Date:  1988-05       Impact factor: 11.105

4.  Simulation of laser tomoscopy in a heterogeneous biological medium.

Authors:  J M Maarek; G Jarry; J Crowe; M H Bui; D Laurent
Journal:  Med Biol Eng Comput       Date:  1986-07       Impact factor: 2.602

5.  Total attenuation coefficients and scattering phase functions of tissues and phantom materials at 633 nm.

Authors:  S T Flock; B C Wilson; M S Patterson
Journal:  Med Phys       Date:  1987 Sep-Oct       Impact factor: 4.071

6.  A Monte Carlo model for the absorption and flux distributions of light in tissue.

Authors:  B C Wilson; G Adam
Journal:  Med Phys       Date:  1983 Nov-Dec       Impact factor: 4.071

Review 7.  Benefits and risks of mammography.

Authors:  S A Feig
Journal:  Recent Results Cancer Res       Date:  1984

8.  Diaphanography: mechanism responsible for the images.

Authors:  D J Watmough
Journal:  Acta Radiol Oncol       Date:  1982

9.  A comparison of physical image quality indices and observer performance in the radiographic detection of nylon beads.

Authors:  L N Loo; K Doi; C E Metz
Journal:  Phys Med Biol       Date:  1984-07       Impact factor: 3.609

10.  Spectral transmittance and contrast in breast diaphanography.

Authors:  S Ertefai; A E Profio
Journal:  Med Phys       Date:  1985 Jul-Aug       Impact factor: 4.071

View more
  2 in total

1.  Multi-layer imaging of human organs by measurement of laser backscattered radiation.

Authors:  S Chacko; M Singh
Journal:  Med Biol Eng Comput       Date:  1999-05       Impact factor: 2.602

2.  Laser reflectance imaging of human organs and comparison with perfusion images.

Authors:  S Shanthi; M Singh
Journal:  Med Biol Eng Comput       Date:  1997-05       Impact factor: 2.602

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.