Literature DB >> 8331933

Intravascular stenting of acute experimental type B dissections.

M R Moon1, M D Dake, L R Pelc, R Liddell, L J Castro, R S Mitchell, D C Miller.   

Abstract

To evaluate the efficacy of intravascular stenting for acute aortic dissection, 12 dogs underwent surgical creation of an acute type B dissection. Intravascular ultrasound evaluated luminal diameter, distal propagation, and branch involvement. Three animals underwent no further treatment (control). In 9 dogs, balloon-expandable intravascular stents (15-20 mm) were placed proximally to compress the intimal flap. One dog with a small dissection had complete obliteration of the false lumen after initial stent placement. Six dogs with extension below the diaphragm were initially stented proximally to restore flow; 3 were left with a residual distal false lumen, while 3 had additional stents placed to obliterate their entire false lumen. In the final 2 dogs, proximal stenting resulted only in partial compression of the false lumen. Two animals died within 24 hr due to prolonged hemodynamic instability and aortic rupture at the intimal flap, respectively. Six weeks later, radiologic and histologic evaluation was performed on the 10 surviving animals. All stented true lumens were patent without thrombus formation, and stents were covered by neointima. In dogs with stenting of the entire dissection, the aortic wall had healed and no false lumen was present. However, in all dogs with only proximal obliteration, 1/2 with partial compression, and 2/3 controls, a patent false channel was present indicative of a chronic dissection. Thus, we found that intravascular stents can restore true lumen flow and obliterate the false lumen in experimental dissections; however, stenting limited to the proximal dissection does not prevent formation of a chronic residual patent false lumen.

Entities:  

Mesh:

Year:  1993        PMID: 8331933     DOI: 10.1006/jsre.1993.1061

Source DB:  PubMed          Journal:  J Surg Res        ISSN: 0022-4804            Impact factor:   2.192


  4 in total

1.  Percutaneous balloon-expandable stents for sealing of acute aortic dissection.

Authors:  A Ramírez; J Suárez de Lezo; M Pan; J Segura; M Romero; D Pavlovic; A Medina
Journal:  Tex Heart Inst J       Date:  2000

Review 2.  TEVAR for type B aortic dissection in Japan.

Authors:  Akihiko Usui
Journal:  Gen Thorac Cardiovasc Surg       Date:  2013-12-10

Review 3.  Malperfusion syndromes in aortic dissections.

Authors:  Todd C Crawford; Robert J Beaulieu; Bryan A Ehlert; Elizabeth V Ratchford; James H Black
Journal:  Vasc Med       Date:  2016-02-08       Impact factor: 3.239

4.  Repair of abdominal aortic aneurysm by transfemoral endovascular graft placement.

Authors:  W S Moore; C L Vescera
Journal:  Ann Surg       Date:  1994-09       Impact factor: 12.969

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.