Literature DB >> 8328940

High-frequency ultrasound quantitative analyses of corneal scarring following excimer laser keratectomy.

N Allemann1, W Chamon, R H Silverman, D T Azar, D Z Reinstein, W J Stark, D J Coleman.   

Abstract

OBJECTIVE: To report objective grading and analysis of excimer laser-induced scarring using high-frequency ultrasound.
METHODS: High-frequency ultrasound (50 MHz) corneal examination was performed on eight New Zealand white rabbits at different time points (10, 17, 24, and 74 days following phototherapeutic keratectomy). We used biometry and signal-processing techniques to determine corneal, epithelial, and scar thicknesses and to quantify the acoustic backscatter.
RESULTS: Excimer laser-induced scarring showed an irregularly distributed acoustic hyperreflectivity that decreased through day 74. Corneal thickness remained reduced after ablation (mean, 318 microns compared with 419 microns for controls). Epithelial thickness averaged 62 microns and scar thickness, 87 microns. Scar peak and average anterior stroma acoustic backscatter ratios decreased from day 10 to day 74 (19.65 to 2.76, and 6.42 to 1.32, respectively). Histopathologic study showed increased keratocyte activity at early time points that correlated with acoustic backscatter ratios and imaging pattern.
CONCLUSIONS: High-frequency ultrasound signal processing is a noninvasive method that quantitatively grades excimer laser-induced corneal scarring.

Entities:  

Mesh:

Year:  1993        PMID: 8328940     DOI: 10.1001/archopht.1993.01090070088025

Source DB:  PubMed          Journal:  Arch Ophthalmol        ISSN: 0003-9950


  6 in total

1.  Corneal wound healing after photorefractive keratectomy: a 3-year confocal microscopy study.

Authors:  Jay C Erie
Journal:  Trans Am Ophthalmol Soc       Date:  2003

2.  Repeatability of layered corneal pachymetry with the artemis very high-frequency digital ultrasound arc-scanner.

Authors:  Dan Z Reinstein; Timothy J Archer; Marine Gobbe; Ronald H Silverman; D Jackson Coleman
Journal:  J Refract Surg       Date:  2009-11-16       Impact factor: 3.573

3.  Automated superficial lamellar keratectomy augmented by excimer laser masked PTK in the management of severe superficial corneal opacities.

Authors:  J L Alio; J Javaloy; J Merayo; A Galal
Journal:  Br J Ophthalmol       Date:  2004-10       Impact factor: 4.638

Review 4.  High-resolution ultrasound imaging of the eye - a review.

Authors:  Ronald H Silverman
Journal:  Clin Exp Ophthalmol       Date:  2008-12-09       Impact factor: 4.207

5.  New algorithm for corneal densitometry assessment based on anterior segment optical coherence tomography.

Authors:  Xiao Yu Wang; Jorge Peraza-Nieves; Tian Qiao Zhang; Anil Rahul Rachwani; Irene Blanco-Domínguez; Carlos Rocha de Lossada; Afredo Manuel Adán-Civiera
Journal:  Eye (Lond)       Date:  2021-08-02       Impact factor: 4.456

6.  Comparison of high-resolution Scheimpflug and high-frequency ultrasound biomicroscopy to anterior-segment OCT corneal thickness measurements.

Authors:  Anastasios John Kanellopoulos; George Asimellis
Journal:  Clin Ophthalmol       Date:  2013-11-20
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.