Variability of forced oscillation (Siemens Siregnost FD 5) measurements of total respiratory resistance in patients and healthy subjects.

F Gimeno1, L T van der Weele, G H Koëter, J G de Monchy, R van Altena.   

Abstract

The reproducibility of total respiratory resistance (Rrs) measured with a simplified forced oscillatory method (Siemens Siregnost FD 5) was measured and compared with that of slow inspiratory vital capacity (IVC) and forced expiratory volume in one second (FEV1). The former technique has the advantage that assessment of bronchial obstruction can be made without a forced maneuver, which may be difficult in patients with chronic obstructive pulmonary disease (COPD). We used the criteria proposed by the American Thoracic Society for the diagnosis of COPD. Pulmonary function tests (IVC, FEV1 and Rrs) were measured in seven healthy subjects and in two groups of patients with COPD. First one technician performed six measurements of IVC, FEV1 and Rrs in all subjects during a period of 90 minutes on the same day. Second to evaluate intraindividual variability the measurements were performed on ten subsequent days. The median interval (range) between the first and last measurements in days was 38 (20-186). The mean +/- SD coefficient of variation (CV) Rrs in patients was 15.7% +/- 5.0% and in normals, 10.8% +/- 3.2%. There was less variation in the FEV1 value of 11.0% +/- 6.2% and normals, 2.2% +/- 1.0%; and IVC, 6.9% +/- 5.0% and normals, 2.4% +/- 0.7%. There is no correlation between age and CV. It is concluded from the study that oscillatory Rrs has a larger coefficient of variation within one patient than FEV1 or IVC. If Rrs is used for longitudinal follow-up in COPD patients, we suggest that variations less than 26% (mean +/- 2 SD) can be considered the result of "spontaneous" variation in lung function.

Entities:  

Mesh:

Year:  1993        PMID: 8328715

Source DB:  PubMed          Journal:  Ann Allergy        ISSN: 0003-4738


  2 in total

1.  Factors for the Variability of Three Acceptable Maximal Expiratory Flow-Volume Curves in Chronic Obstructive Pulmonary Disease.

Authors:  Masafumi Yamamoto; Satoshi Konno; Hironi Makita; Katsuaki Nitta; Kaoruko Shimizu; Masaru Suzuki; Mutsumi Nishida; Junichi Sugita; Takanori Teshima; Masaharu Nishimura
Journal:  Int J Chron Obstruct Pulmon Dis       Date:  2021-02-24

2.  Long-term variability of impulse oscillometry and spirometry in stable COPD and asthma.

Authors:  Jianhua Xu; Xingxing Sun; Hanqing Zhu; Yuan Cao; Bigyan Pudasaini; Wenlan Yang; Jinming Liu; Jian Guo
Journal:  Respir Res       Date:  2022-09-21
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.