Literature DB >> 8327686

Functional images of hepatic perfusion obtained with dynamic CT.

K A Miles1, M P Hayball, A K Dixon.   

Abstract

A dynamic computed tomographic (CT) technique for separate quantification of arterial and portal components of liver perfusion with functional imaging was developed and used to study 24 livers. A single-location dynamic sequence was performed after intravenous administration of a 50-mL bolus of contrast medium. The time to maximum splenic enhancement was used to differentiate arterial and portal phases, and the maximal slopes of the liver time-density curve in each phase were used to calculate both arterial and portal perfusion. The arterial/total perfusion ratio was also calculated. The values of these parameters for individual pixels were used to create functional images. Arterial perfusion was increased in patients with metastases and cirrhosis. Portal perfusion was reduced in patients with cirrhosis. Functional images were successfully created in all but one case. The technique enables quantification and functional mapping of several perfusion parameters with a spatial resolution greater than that achieved with other imaging techniques.

Entities:  

Mesh:

Year:  1993        PMID: 8327686     DOI: 10.1148/radiology.188.2.8327686

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  76 in total

Review 1.  Applications of imaging technology in radiation research.

Authors:  MingDe Lin; Edward F Jackson
Journal:  Radiat Res       Date:  2012-03-08       Impact factor: 2.841

2.  Hepatic computed tomography perfusion: comparison of maximum slope and dual-input single-compartment methods.

Authors:  Tomonori Kanda; Takeshi Yoshikawa; Yoshiharu Ohno; Naoki Kanata; Hisanobu Koyama; Munenobu Nogami; Daisuke Takenaka; Kazuro Sugimura
Journal:  Jpn J Radiol       Date:  2010-12-30       Impact factor: 2.374

Review 3.  Prediction of liver cirrhosis, using diagnostic imaging tools.

Authors:  Suk Keu Yeom; Chang Hee Lee; Sang Hoon Cha; Cheol Min Park
Journal:  World J Hepatol       Date:  2015-08-18

4.  Dynamic contrast-enhanced CT in suspected lung cancer: quantitative results.

Authors:  S W Harders; H H Madsen; H M Nellemann; T R Rasmussen; J Thygesen; H Hager; N T Andersen; F Rasmussen
Journal:  Br J Radiol       Date:  2013-09-12       Impact factor: 3.039

5.  Perfusion computed tomography evaluation of angiogenesis in liver cancer.

Authors:  Han Feng Yang; Yong Du; Jia Xiang Ni; Xiang Ping Zhou; Jin Dong Li; Qing Zhang; Xiao Xue Xu; Yang Li
Journal:  Eur Radiol       Date:  2010-02-24       Impact factor: 5.315

6.  Quantitative tissue blood flow measurement of the liver parenchyma: comparison between xenon CT and perfusion CT.

Authors:  Kazuhiko Hashimoto; Takamichi Murakami; Keizo Dono; Masatoshi Hori; Tonsok Kim; Masayuki Kudo; Shigeru Marubashi; Atsushi Miyamoto; Yutaka Takeda; Hiroaki Nagano; Koji Umeshita; Hironobu Nakamura; Morito Monden
Journal:  Dig Dis Sci       Date:  2007-02-23       Impact factor: 3.199

7.  Perfusion CT best predicts outcome after radioembolization of liver metastases: a comparison of radionuclide and CT imaging techniques.

Authors:  Fabian Morsbach; Bert-Ram Sah; Lea Spring; Gilbert Puippe; Sonja Gordic; Burkhardt Seifert; Niklaus Schaefer; Thomas Pfammatter; Hatem Alkadhi; Caecilia S Reiner
Journal:  Eur Radiol       Date:  2014-05-12       Impact factor: 5.315

8.  Contrast-enhanced ultrasound for quantitative assessment of portal pressure in canine liver fibrosis.

Authors:  Lin Zhai; Lan-Yan Qiu; Yuan Zu; Yan Yan; Xiao-Zhuan Ren; Jun-Feng Zhao; Yu-Jiang Liu; Ji-Bin Liu; Lin-Xue Qian
Journal:  World J Gastroenterol       Date:  2015-04-21       Impact factor: 5.742

9.  The use of perfusion CT for the evaluation of therapy combining AZD2171 with gefitinib in cancer patients.

Authors:  Martijn R Meijerink; Hester van Cruijsen; Klaas Hoekman; Matthijs Kater; Cors van Schaik; Jan Hein T M van Waesberghe; Giuseppe Giaccone; Radu A Manoliu
Journal:  Eur Radiol       Date:  2006-10-27       Impact factor: 5.315

10.  [Perfusion computed tomography for diffuse liver diseases].

Authors:  S A Schmidt; M S Juchems
Journal:  Radiologe       Date:  2012-08       Impact factor: 0.635

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.