Literature DB >> 8325205

Comparison of bolus and infusion protocols for determining acute insulin response to intravenous glucose in normal humans. The ICARUS Group. Islet Cell Antibody Register User's Study.

D K McCulloch1, P J Bingley, P G Colman, R A Jackson, E A Gale.   

Abstract

OBJECTIVE: To help standardize methodology for intravenous glucose tolerance testing in preclinical IDDM by comparing a 30-s bolus and a 3-min infusion of glucose. RESEARCH DESIGN AND METHODS: We tested 20 healthy nondiabetic adults at four centers (in Seattle, Boston, Melbourne, and London). Each subject had four intravenous glucose tolerance tests (two bolus and two infusion). The acute insulin response to glucose was calculated as the mean of the 1' + 3', the mean of 1' to 10', or as the integrated area from 0 to 10'. Glucose and insulin profiles and intrasubject coefficient of variation were compared.
RESULTS: With the infusion protocol, the 1' insulin was significantly higher, resulting in a higher acute insulin response to glucose when calculated as 1' + 3' (525 +/- 66 vs. 376 +/- 35 pM, P < 0.004). When calculated over 10 min, however, the acute insulin response to glucose was not different between protocols. In addition, the intrasubject coefficient of variation was significantly better when calculated over 10 min in both protocols, but no significant differences were noted between the bolus and infusion (infusion: AIRg [area from 0 to 10'] 10.4 +/- 2.1% vs. AIRg [1' + 3'] 14.9 +/- 2.8%, P < 0.007; bolus: AIRg [area from 0 to 10'] 14.6 +/- 2.8% vs. AIRg [1' + 3'] 19.8 +/- 3.5%, P < 0.007). Comparison of the insulin assays between the four centers showed close correlation and gave indistinguishable results in terms of within-subject coefficient of variation. Glucose profiles were similar in both protocols. Although the glucose values were lower with the bolus protocol from 4' to 40', the rate of fall from 10 to 30' (and thus the rate of glucose disposal) was indistinguishable between the two.
CONCLUSIONS: These data suggest that neither protocol gives significant advantage over the other. However, to allow comparison of the acute insulin response to glucose between different protocols used in centers around the world, the ICARUS 3-min infusion protocol is recommended, with acute insulin response to glucose calculated over 10 min after the end of glucose administration; this reduces the within-subject coefficient of variation and provides similar acute insulin response to glucose with both protocols.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8325205     DOI: 10.2337/diacare.16.6.911

Source DB:  PubMed          Journal:  Diabetes Care        ISSN: 0149-5992            Impact factor:   19.112


  4 in total

1.  Prevention of insulin-dependent diabetes mellitus--wishful thinking, or reality?

Authors:  J Palmer
Journal:  West J Med       Date:  1996-03

2.  Intervening before the onset of Type 1 diabetes: baseline data from the European Nicotinamide Diabetes Intervention Trial (ENDIT).

Authors: 
Journal:  Diabetologia       Date:  2003-02-27       Impact factor: 10.122

3.  High frequency of abnormal glucose tolerance in DQA1*0102/DQB1*0602 relatives identified as part of the Diabetes Prevention Trial--Type 1 Diabetes.

Authors:  C J Greenbaum; G Eisenbarth; M Atkinson; L Yu; S Babu; D Schatz; A Zeidler; T Orban; C Wasserfall; D Cuthbertson; J Krischer
Journal:  Diabetologia       Date:  2004-12-16       Impact factor: 10.122

4.  Progression to type 1 diabetes in islet cell antibody-positive relatives in the European Nicotinamide Diabetes Intervention Trial: the role of additional immune, genetic and metabolic markers of risk.

Authors:  P J Bingley; E A M Gale
Journal:  Diabetologia       Date:  2006-03-03       Impact factor: 10.122

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.