Factors affecting delivery of high-efficiency dialysis using temporary vascular access.

J Kelber1, J A Delmez, D W Windus.   

Abstract

The effectiveness of hemodialysis depends, in part, on the delivery of the prescribed rate of blood flow and the amount of blood recirculation. Studies evaluating the magnitude of recirculation in double-lumen catheters at blood flow rates > or = 300 mL/min have not been performed. We therefore examined the effects of prescribed blood flow rate and placement site on measure blood flow, recirculation and effective clearance using double-lumen catheters in 17 patients. Double-lumen catheters were placed in the internal jugular (12.5 cm), subclavian (20 cm), and femoral veins (15 cm and 24 cm). Recirculation studies were performed in triplicate with a two-needle method at blood flow rates of 250, 300, 350, and 400 mL/min. Blood flow rate was measured with an ultrasonic flow meter placed on the venous line. The arterial line pressure was continuously monitored. Mean arterial line pressure was -105 +/- mm Hg at 250 mL/min and -231 +/- mm Hg at 400 mL/min prescribed blood flow rates in the internal jugular, subclavian, and 15-cm femoral vein catheters. Patients with 24-cm femoral catheters had a mean arterial line pressure of -196 +/- mm Hg at 250 mL/min and -327 +/- mm Hg at 400 mL/min. In spite of the change in arterial line pressure, measured blood flow rate increased appropriately at all set blood flows and with all catheter sites studied.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1993        PMID: 8322789     DOI: 10.1016/s0272-6386(12)70162-2

Source DB:  PubMed          Journal:  Am J Kidney Dis        ISSN: 0272-6386            Impact factor:   8.860


  5 in total

1.  Regional citrate anticoagulation and influence of recirculation on ionized calcium levels in the circuit.

Authors:  Anais Degraeve; Etienne Danse; Pierre-François Laterre; Philippe Hantson; Alexis Werion
Journal:  J Artif Organs       Date:  2019-08-23       Impact factor: 1.731

2.  Vascular Access Site for Renal Replacement Therapy in Acute Kidney Injury: A Post hoc Analysis of the ATN Study.

Authors:  Yue-Harn Ng; Kavitha Ganta; Herbert Davis; V Shane Pankratz; Mark Unruh
Journal:  Front Med (Lausanne)       Date:  2017-04-11

3.  Initial Clinical Experience with a Symmetric Tip Tunneled Hemodialysis Catheter Without Side Holes.

Authors:  Michael G Tal; Alexander S Yevzlin
Journal:  ASAIO J       Date:  2021-11-01       Impact factor: 2.872

4.  Renal replacement therapy in the intensive care unit.

Authors:  Neesh Pannu; Rt Noel Gibney
Journal:  Ther Clin Risk Manag       Date:  2005-06       Impact factor: 2.423

5.  Clot accumulation at the tip of hemodialysis catheters in a large animal model.

Authors:  Michael G Tal; Ron Livne; Rotem Neeman
Journal:  J Vasc Access       Date:  2020-12-25       Impact factor: 2.283

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.