Literature DB >> 8317751

Heat loss in humans covered with cotton hospital blankets.

D I Sessler1, M Schroeder.   

Abstract

We evaluated mean skin temperature, cutaneous heat loss, and perceived warmth in six volunteers covered with one or three cotton hospital blankets, warmed or unwarmed. Mean skin temperatures were significantly higher during each treatment than during the control periods preceding each blanket application. Total cutaneous heat loss during the control period was 81 +/- 11 watts. Covering the volunteers with a single warmed or unwarmed blanket for 60 min reduced heat loss 33% +/- 5%; when they were covered with three warmed or unwarmed blankets, heat loss was reduced an additional 18% +/- 6%. Warmed blankets reduced heat loss 9-16 watts more than unwarmed ones, but the benefit dissipated in approximately 10 min. The volunteers' perception of warmth was similar when they were covered with three warmed or unwarmed blankets; it also was similar when they were covered with a single warmed or unwarmed blanket. These data indicate that increasing the number of covering blankets from one to three decreases heat loss only slightly. Similarly, warming the blankets is relatively ineffective and the benefit short-lived. The reduction in heat loss, even by three warmed blankets replaced at 10-min intervals, was small compared to that provided by available active warming systems.

Entities:  

Mesh:

Year:  1993        PMID: 8317751     DOI: 10.1213/00000539-199307000-00014

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  13 in total

1.  Effects of a circulating-water garment and forced-air warming on body heat content and core temperature.

Authors:  Akiko Taguchi; Jebadurai Ratnaraj; Barbara Kabon; Neeru Sharma; Rainer Lenhardt; Daniel I Sessler; Andrea Kurz
Journal:  Anesthesiology       Date:  2004-05       Impact factor: 7.892

2.  Effect of amino acid infusion on central thermoregulatory control in humans.

Authors:  Yasufumi Nakajima; Akira Takamata; Takashi Matsukawa; Daniel I Sessler; Yoshihiro Kitamura; Hiroshi Ueno; Yoshifumi Tanaka; Toshiki Mizobe
Journal:  Anesthesiology       Date:  2004-03       Impact factor: 7.892

3.  Estimation of mean body temperature from mean skin and core temperature.

Authors:  Rainer Lenhardt; Daniel I Sessler
Journal:  Anesthesiology       Date:  2006-12       Impact factor: 7.892

Review 4.  [Perioperative thermal management].

Authors:  A Bräuer; T Perl; M Quintel
Journal:  Anaesthesist       Date:  2006-12       Impact factor: 1.041

5.  Full body forced air warming: commercial blanket vs air delivery beneath bed sheets.

Authors:  P M Kempen
Journal:  Can J Anaesth       Date:  1996-11       Impact factor: 5.063

6.  Dantrolene reduces the threshold and gain for shivering.

Authors:  Chun-Ming Lin; Sharma Neeru; Anthony G Doufas; Edwin Liem; Yunus Muneer Shah; Anupama Wadhwa; Rainer Lenhardt; Andrew Bjorksten; Akiko Taguchi; Barhara Kabon; Daniel I Sessler; Andrea Kurz
Journal:  Anesth Analg       Date:  2004-05       Impact factor: 5.108

7.  Blood pressure response to thermoregulatory vasoconstriction during isoflurane and desflurane anesthesia.

Authors:  R Greif; S Laciny; A Rajek; A G Doufas; D I Sessler
Journal:  Acta Anaesthesiol Scand       Date:  2003-08       Impact factor: 2.105

Review 8.  Temperature monitoring and perioperative thermoregulation.

Authors:  Daniel I Sessler
Journal:  Anesthesiology       Date:  2008-08       Impact factor: 7.892

9.  The effect of electrically heated humidifier on the body temperature and blood loss in spinal surgery under general anesthesia.

Authors:  Hyun Kyu Lee; Yeon-Hee Jang; Kwan-Woong Choi; Jae Ho Lee
Journal:  Korean J Anesthesiol       Date:  2011-08-23

10.  Comparison of three different prehospital wrapping methods for preventing hypothermia--a crossover study in humans.

Authors:  Øyvind Thomassen; Hilde Færevik; Øyvind Østerås; Geir Arne Sunde; Erik Zakariassen; Mariann Sandsund; Jon Kenneth Heltne; Guttorm Brattebø
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2011-06-23       Impact factor: 2.953

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.