Literature DB >> 8312417

The impact of peritonitis on peritoneal and systemic acid-base status of patients on continuous ambulatory peritoneal dialysis.

J J Sennesael1, G C De Smedt, P Van der Niepen, D L Verbeelen.   

Abstract

OBJECTIVE: To assess the possible effects of peritonitis on peritoneal and systemic acid-base status.
DESIGN: pH, pCO2, lactate, and total leukocyte and differential count were simultaneously determined in the overnight dwell peritoneal dialysis effluent (PDE) and arterial blood in noninfected patients (controls) and on days 1, 3, and 5 from the onset of peritonitis.
SETTING: University multidisciplinary dialysis program. PATIENTS: Prospective analysis of 63 peritonitis episodes occurring in 30 adult CAPD patients in a single center.
RESULTS: In controls, mean (+/- SD) acid-base parameters were pH 7.41 +/- 0.05, pCO2 43.5 +/- 2.6 mm Hg, lactate 2.5 +/- 1.5 mmol/L in the PDE, and pH 7.43 +/- 0.04, PaCO2 36.8 +/- 3.8 mm Hg, lactate 1.4 +/- 0.7 mmol/L in the blood. In sterile (n = 6), gram-positive (n = 34), and Staphylococcus aureus (n = 9) peritonitis PDE pH's on day 1 were, respectively, 7.29 +/- 0.07, 7.32 +/- 0.07, and 7.30 +/- 0.08 (p < 0.05 vs control). In gram-negative peritonitis (n = 14) PDE pH was 7.21 +/- 0.08 (p < 0.05 vs all other groups). A two-to-threefold increase in PDE lactate was observed in all peritonitis groups, but a rise in pCO2 was only seen in gram-negative peritonitis. Acid-base profile of PDE had returned to control values by day 3 in sterile, gram-positive and Staphylococcus aureus peritonitis and by day 5 in gram-negative peritonitis. Despite a slight increase in plasma lactate on the first day of peritonitis, arterial blood pH was not affected by peritonitis.
CONCLUSION: PDE pH is decreased in continuous ambulatory peritoneal dialysis (CAPD) peritonitis, even in the absence of bacterial growth. In gram-negative peritonitis, PDE acidosis is more pronounced and prolonged, and pCO2 is markedly increased. Arterial blood pH is not affected by peritonitis.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8312417

Source DB:  PubMed          Journal:  Perit Dial Int        ISSN: 0896-8608            Impact factor:   1.756


  3 in total

Review 1.  Peritoneal dialysis. Prevention and control of infection.

Authors:  R Gokal
Journal:  Drugs Aging       Date:  2000-10       Impact factor: 3.923

2.  Convergence of biological nitration and nitrosation via symmetrical nitrous anhydride.

Authors:  Dario A Vitturi; Lucia Minarrieta; Sonia R Salvatore; Edward M Postlethwait; Marco Fazzari; Gerardo Ferrer-Sueta; Jack R Lancaster; Bruce A Freeman; Francisco J Schopfer
Journal:  Nat Chem Biol       Date:  2015-05-25       Impact factor: 15.040

Review 3.  Bioresponsive drug delivery systems for the treatment of inflammatory diseases.

Authors:  Yin Dou; Chenwen Li; Lanlan Li; Jiawei Guo; Jianxiang Zhang
Journal:  J Control Release       Date:  2020-09-08       Impact factor: 9.776

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.