Literature DB >> 8309743

Lung function and bronchial challenges in infants: repeatability of histamine and comparison with methacholine challenges.

S M Stick1, D J Turner, P N LeSouëf.   

Abstract

UNLABELLED: Limited information exists regarding the repeatability of lung function and bronchial challenge tests using the rapid thoracic compression technique (RTC) in infants. AIMS: To determine the repeatability of lung function and histamine challenge test results using the RTC technique and to compare the results obtained for bronchial challenges using histamine (H) and methacholine (M).
METHODS: Twelve infants [7 healthy, 5 with cystic fibrosis (CF) had pairs of H challenges 1 week apart. Eleven infants (7 healthy, 4 CF) had one H and one M challenge a week apart. The provocative concentration of H or M to cause a 40% fall in maximum flow at functional residual capacity (PC40) was determined using the RTC technique. Twenty-three comparisons were possible between maximal expiratory flow at functional residual capacity (VmaxFRC) measurements made 1 week apart.
RESULTS: The mean difference between pairs of VmaxFRC measurements was 6.4% of baseline, and the coefficient of repeatability was 31.1% of baseline. The mean difference between PC40(H) measurements was 0.163 doubling concentrations, with a coefficient of repeatability of 1.66 doubling concentrations. The mean difference between PC40(H) and PC40(M) was 0.75 doubling concentrations, with 95% of PC40(H) between -0.18 to 1.69 doubling concentrations of the PC40(M).
CONCLUSIONS: Although the repeatability of VmaxFRC using the RTC technique is less than for voluntary forced expiratory flow parameters in older children, similar results were obtained for infants as observed in older subjects for repeatability of H challenges and agreement between measures of bronchial responsiveness using H or M.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8309743     DOI: 10.1002/ppul.1950160308

Source DB:  PubMed          Journal:  Pediatr Pulmonol        ISSN: 1099-0496


  4 in total

1.  Repeatability of lung function tests during methacholine challenge in wheezy infants.

Authors:  C Delacourt; M R Benoist; S Waernessyckle; P Rufin; J J Brouard; J de Blic; P Scheinmann
Journal:  Thorax       Date:  1998-11       Impact factor: 9.139

Review 2.  Monitoring early inflammation in CF. Infant pulmonary function testing.

Authors:  Jack K Sharp
Journal:  Clin Rev Allergy Immunol       Date:  2002-08       Impact factor: 8.667

3.  The effects of inhaled beclomethasone dipropionate on lung function and histamine responsiveness in recurrently wheezy infants.

Authors:  S M Stick; P R Burton; J B Clough; M Cox; P N LeSouëf; P D Sly
Journal:  Arch Dis Child       Date:  1995-10       Impact factor: 3.791

4.  Comparison Study of Airway Reactivity Outcomes due to a Pharmacologic Challenge Test: Impulse Oscillometry versus Least Mean Squared Analysis Techniques.

Authors:  Elena Rodriguez; Charrell M Bullard; Milena H Armani; Thomas L Miller; Thomas H Shaffer
Journal:  Pulm Med       Date:  2013-04-11