Assessment of the accuracy of stereotactic radiosurgery using Fricke-infused gels and MRI.

R J Schulz1, M J Maryanski, G S Ibbott, J E Bond.   

Abstract

The treatment plans for stereotactic radiosurgery employ small, circular, noncoplanar fields applied in a series of arcs, or with synchronous rotation of the accelerator gantry and patient support assembly. Primary or metastatic brain tumors and arterial-venous malformations are localized in relation to a stereotactic head frame using CT, MRI, and angiography. As x-ray doses in the range of 20-40 Gy are delivered in a single treatment, it is critical that the dose distribution produced by the accelerator accurately reflect the one developed by the treatment planning computer. Until the advent of Fricke-infused gels, whose NMR characteristics are changed by irradiation, there was no practical method for assessing the accuracy of x-ray beam positioning on a target that was localized by both CT and MRI. A stereotactic head frame was attached to a hollow glass head filled with a Fricke-infused gel. A 2-mm target point at approximately the center of this manikin was localized by CT and MRI. The head frame was then mounted to the patient support assembly of a linear accelerator, and given a dose of 40 Gy to the isocenter from 6-MV x rays using a modified version of the dynamic stereotactic radiosurgery plan developed in Montreal. Subsequent MRI showed the target point at the center of the dose distribution, thus confirming the accuracy of the stereotactic radiosurgery procedure. This demonstrated the unique characteristics of the Fricke-infused gel for the simultaneous localization of x-ray beams in three dimensions.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8309446     DOI: 10.1118/1.597126

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

1.  Fast, high-resolution 3D dosimetry utilizing a novel optical-CT scanner incorporating tertiary telecentric collimation.

Authors:  H S Sakhalkar; M Oldham
Journal:  Med Phys       Date:  2008-01       Impact factor: 4.071

2.  A comprehensive evaluation of the PRESAGE/optical-CT 3D dosimetry system.

Authors:  H S Sakhalkar; J Adamovics; G Ibbott; M Oldham
Journal:  Med Phys       Date:  2009-01       Impact factor: 4.071

3.  Adaptation of radiation field analyser (RFA) as optical CT scanner for gel dosimetry.

Authors:  S Brindha; Vinoth Kumar; S Vasanth; B Ravindran Paul
Journal:  J Med Phys       Date:  2006-01

Review 4.  Radiation Dosimetry by Use of Radiosensitive Hydrogels and Polymers: Mechanisms, State-of-the-Art and Perspective from 3D to 4D.

Authors:  Yves De Deene
Journal:  Gels       Date:  2022-09-19

5.  Development of a dedicated phantom for multi-target single-isocentre stereotactic radiosurgery end to end testing.

Authors:  Joel Poder; Ryan Brown; Harry Porter; Rashmi Gupta; Anna Ralston
Journal:  J Appl Clin Med Phys       Date:  2018-09-16       Impact factor: 2.102

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.