[Removal of infected total pacemaker system under extracorporeal circulation--a case report and review of the Japanese literature].

H Shimizu1, R Yozu, T Ueda, T Goto, Y Soma, S Kawada.   

Abstract

A 35-year-old male with sick sinus syndrome was complicated with recurrent local infection at the site of the generator pocket associate with a retained pacemaker lead, followed by septicemia presenting with Staphylococcus aureus. Several attempts to remove the lead via the implantation vein by direct traction were performed unsuccessfully because the leads were strongly adhered to the trabecula of the right ventricle. Repeated debridement employing antibiotic therapy was ineffective. As a last resort, we finally operated under extracorporeal circulation (ECC) 24 months after the first implantation and 22 months after initiation of the local infectious episode. As we found it difficult to remove the leads by traction even under direct vision, we used the vinyl chloride tube, which is a part of the ECC circuit, as a sheath for applying countertraction around the lead tip to prevent the myocardial wall from being torn and extracted together with the lead tip. The lead was removed successfully and a new epicardial lead was implanted. The postoperative course uneventful and no recurrence has occurred after 1 year. In reviewing the Japanese literature, 10 case, operated on under ECC to remove the infected retained leads, were described in detail. Among them, eight cases had undergone previous debridement including removal of the generator and the subcutaneous portion of the lead. It is clear that removal of all of the pacemaker system is necessary for eradication of infection. Adhesion of the lead to the wall is firm. Only one case besides ours succeeded in having its lead removed without requiring incision of the tissue around the lead tip.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1994        PMID: 8308377

Source DB:  PubMed          Journal:  Nihon Kyobu Geka Gakkai Zasshi        ISSN: 0369-4739


  2 in total

1.  Outcomes after endocarditis or device infection in patients with left ventricular epicardial leads versus coronary sinus leads.

Authors:  Saima Karim; Ayman Hussein; Omar Batal; Mohammad M Karim; Khaldoun Tarakji; Walid Saliba; David Martin; Oussama Wazni; Mohammed Kanj; Bruce L Wilkoff; Thomas Callahan
Journal:  J Interv Card Electrophysiol       Date:  2014-02-23       Impact factor: 1.900

2.  Is there an adverse outcome from abandoned pacing leads?

Authors:  C Suga; D L Hayes; L K Hyberger; M A Lloyd
Journal:  J Interv Card Electrophysiol       Date:  2000-10       Impact factor: 1.900