Literature DB >> 8303444

Effects of anterior vertebral grafting on the traumatized lumbar spine after pedicle screw-plate fixation.

D J Maiman1, F Pintar, N Yoganandan, J Reinartz.   

Abstract

This study was conducted to determine the effects of corpectomy and anterior strut grafting on the biomechanics of traumatized lumbar spine after pedicle screw-plate fixation. Eight lumbar spines were loaded until fracture (initial cycle) and then reloaded to the same deformation (injury cycle). After transpedicular fixation, spines were again loaded (fixation cycle). Partial corpectomy of the fractured body and anterior strut grafting were accomplished; the spine reloaded (strut cycle). Spine angles were measured and biomechanical strength and kinematic parameters analyzed. Load-deformation relationships were similar for fixation and strut cycles until maximum load; at failure, loads were higher for the former (P < 0.05), however. Alignment was improved by stabilization or stabilization plus anterior grafting (P < 0.05). Vertebral height was best maintained by grafting as an adjunct to pedicle fixation (P < 0.05). Kinematics were largely unaffected by grafting, except for reduced motion at the posterior vertebral targets between the fixated levels (P < 0.05). The strength of the fixated spine is relatively unchanged by corpectomy and anterior grafting; alignment may be improved in the latter group.

Entities:  

Mesh:

Year:  1993        PMID: 8303444     DOI: 10.1097/00007632-199312000-00010

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  3 in total

1.  Multivariate analysis of risk factors for predicting supplementary posterior instrumentation after anterolateral decompression and instrumentation in treating thoracolumbar burst fractures.

Authors:  Jiang Chen; Yu-Song Jia; Qi Sun; Jin-Yu Li; Chen-Ying Zheng; Jian Du; Chun-Xiao Bai
Journal:  J Orthop Surg Res       Date:  2015-01-28       Impact factor: 2.359

2.  Reduction of the domino effect in osteoporotic vertebral compression fractures through short-segment fixation with intravertebral expandable pillars compared to percutaneous kyphoplasty: a case control study.

Authors:  Jui-Yang Hsieh; Chung-Ding Wu; Ting-Ming Wang; Hsuan-Yu Chen; Chui-Jia Farn; Po-Quang Chen
Journal:  BMC Musculoskelet Disord       Date:  2013-03-02       Impact factor: 2.362

3.  Surgical management of minimally invasive anterior lumbar interbody fusion with stand-alone interbody cage for L4-5 degenerative disorders: clinical and radiographic findings.

Authors:  Yasuo Hironaka; Tetsuya Morimoto; Yasushi Motoyama; Young-Su Park; Hiroyuki Nakase
Journal:  Neurol Med Chir (Tokyo)       Date:  2013-10-21       Impact factor: 1.742

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.