Literature DB >> 8302524

Quantitating cataract and nuclear brunescence, the Harvard and LOCS systems.

L T Chylack1, J K Wolfe, J Friend, P M Khu, D M Singer, D McCarthy, J del Carmen, B Rosner.   

Abstract

Subjective and objective systems are used to quantify cataract at The Center for Clinical Cataract Research. We have described each system and its use, presented data on reproducibility and validity, and for objective systems, demonstrated the correlation to the subjective grade of the cataract as defined by the Lens Opacities Classification Systems, Versions II and III (LOCS II and III). The subjective systems are used to classify nuclear color, nuclear opalescence, cortical cataract, and posterior subcapsular cataract. Reported kappa scores for LOCS II range from 0.85 to 1.0. Intraclass correlation coefficients for LOCS III (r1) range from 0.67 to 0.94. The computerized objective system are: (1) fast spectral scanning colorimetry (FSSC) for assessment of nuclear color (r1 = 0.96 to 0.98); (2) nuclear mean density (NMD) for assessment of nuclear opalescence (r1 = 0.97); and (3) percent area opacity (anterior = a; posterior = p) (OPAC-a and OPAC-p) for assessment of cortical and posterior subcapsular cataract (r1 = 0.92 to 0.96).

Entities:  

Mesh:

Year:  1993        PMID: 8302524     DOI: 10.1097/00006324-199311000-00005

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  7 in total

Review 1.  [Clinical, morphological and molecular biological characteristics of the aging eye].

Authors:  M R R Böhm; H Thomasen; F Parnitzke; K-P Steuhl
Journal:  Ophthalmologe       Date:  2017-02       Impact factor: 1.059

2.  Vitamin C mediates chemical aging of lens crystallins by the Maillard reaction in a humanized mouse model.

Authors:  Xingjun Fan; Lixing W Reneker; Mark E Obrenovich; Christopher Strauch; Rongzhu Cheng; Simon M Jarvis; Beryl J Ortwerth; Vincent M Monnier
Journal:  Proc Natl Acad Sci U S A       Date:  2006-10-30       Impact factor: 11.205

3.  Vitamin C-mediated Maillard reaction in the lens probed in a transgenic-mouse model.

Authors:  Xingjun Fan; Vincent M Monnier
Journal:  Ann N Y Acad Sci       Date:  2008-04       Impact factor: 5.691

4.  Automated, computerized, feature-based phenotype analysis of slit lamp images of the mouse lens.

Authors:  Jenny Yuen; Yi Li; Linda G Shapiro; John I Clark; Ernest Arnett; E Helene Sage; James F Brinkley
Journal:  Exp Eye Res       Date:  2007-12-07       Impact factor: 3.467

5.  Clinical results after microincision biaxial cataract surgery and implantation of an Incise intraocular lens.

Authors:  Wojciech Lubiński; Marta Kirkiewicz; Karolina Podborączyńska-Jodko
Journal:  Int Ophthalmol       Date:  2017-08-12       Impact factor: 2.031

6.  The effect of aging on the eccentricity dependency of orientation anisotropy of perceptual surround suppression.

Authors:  Menaka S Malavita; Trichur R Vidyasagar; Allison M McKendrick
Journal:  J Vis       Date:  2021-01-04       Impact factor: 2.240

Review 7.  Phakic intraocular lenses: An overview.

Authors:  Soraya M R Jonker; Tos T J M Berendschot; Isabelle E Y Saelens; Noël J C Bauer; Rudy M M A Nuijts
Journal:  Indian J Ophthalmol       Date:  2020-12       Impact factor: 1.848

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.