Comparison between the flicker test procedures of Aulhorn and of Dölle in the diagnosis of optic neuritis.

C Stellberger1, W Wetzel, G Duncker.   

Abstract

The use of the flicker test for diagnostic purposes is based on the absence of Brücke's effect during acute inflammation of the optic nerve. The test device of Aulhorn was compared with another, less expensive flicker test device, that of Dölle. The flicker test device of Aulhorn uses a mechanical projection system. In the device of Dölle, the flicker field is formed by electronically controlled groups of light-emitting diodes. In an initial examination, the reliability of Aulhorn's test was slightly higher than of Dölle's procedure. The normal ranges in 45 healthy subjects differed markedly between the two methods. One hundred and fifteen eyes of patients with established or suspected optic neuritis were also examined. Although there were differences in some conditions (e.g. shape and homogeneity of flicker field) due to the techniques, the specificity and sensitivity of the two methods were similar concerning the diagnosis of acute optic neuritis.

Entities:  

Mesh:

Year:  1993        PMID: 8299976     DOI: 10.1007/BF00919283

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  7 in total

1.  Flicker fusion frequency; background and applications.

Authors:  E SIMONSON; J BROZEK
Journal:  Physiol Rev       Date:  1952-07       Impact factor: 37.312

2.  Standardization of the Tübingen flicker test.

Authors:  S Trauzettel-Klosinski; M Schüpbach; E Aulhorn
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1989       Impact factor: 3.117

3.  [Normal values in the Aulhorn flicker test].

Authors:  T Christ; R Stodtmeister; L Pillunat
Journal:  Klin Monbl Augenheilkd       Date:  1987-02       Impact factor: 0.700

4.  [Significance of the Tübingen flicker test in the differential diagnosis of optic neuritis].

Authors:  S Trauzettel-Klosinski; E Aulhorn
Journal:  Fortschr Ophthalmol       Date:  1988

5.  [Changes in visual evoked potential latencies following retrobulbar neuritis].

Authors:  H Gruber
Journal:  Klin Monbl Augenheilkd       Date:  1990-07       Impact factor: 0.700

6.  [The flicker test--a new simple procedure for the diagnosis of neuritis of the optic nerve].

Authors:  E Aulhorn; S Trauzettel-Klosinski
Journal:  Fortschr Ophthalmol       Date:  1983

7.  [Significance of the flicker test for follow-up and prognosis in optic nerve neuritis].

Authors:  S Trauzettel-Klosinski
Journal:  Klin Monbl Augenheilkd       Date:  1986-01       Impact factor: 0.700

  7 in total
  1 in total

Review 1.  [Practical significance of critical fusion frequency (CFF). Chronological resolution of the visual system in differential diagnosis].

Authors:  H Baatz; P Raak; D de Ortueta; A Mirshahi; G Scharioth
Journal:  Ophthalmologe       Date:  2010-08       Impact factor: 1.059

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.