Literature DB >> 8297033

Glucose electrodes based on cross-linked [Os(bpy)2Cl]+/2+ complexed poly(1-vinylimidazole) films.

T J Ohara1, R Rajagopalan, A Heller.   

Abstract

Enzyme electrodes based on a redox hydrogel formed upon complexing water-soluble poly(1-vinylimidazole) (PVI) with [Os(bpy)2Cl]+ and cross-linked with water-soluble poly(ethylene glycol) diglycidyl ether (molecular weight 400, peg 400) are described. The properties of the electrodes depended on their polymers' osmium content, the extent of cross-linking, the pH, and the ionic strength in which they were used. The redox hydrogels' electron diffusion coefficients (De) increased with osmium content of their polymers. The De values were 1.5 x 10(-8), 1.3 x 10(-8), and 4.3 x 10(-9) cm2/s for PVI3-Os, PVI5-Os, and PVI10-Os, respectively, the subscripts indicating the number of monomer units per osmium redox center. De decreased with increasing ionic strength and increased upon protonation of the polymer. In glucose electrodes, made by incorporating into their films glucose oxidase (GOX) through covalent bonding in the cross-linking step, glucose was electrooxidized at > 150 mV (SCE). The characteristics of these electrodes depended on the GOX concentration, film thickness, O2 concentration, pH, NaCl concentration, and electrode potential. The steady-state glucose electrooxidation currents were independent of the polymers' osmium content in the studied (3-10 monomer units per osmium center) range. Electrodes containing 39% GOX reached steady-state glucose electrooxidation current densities of 400 microA/cm2 and, when made with thick gel films, were selective for glucose in the presence of physiological concentrations of ascorbate and acetaminophen.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8297033     DOI: 10.1021/ac00071a031

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  4 in total

Review 1.  Enzymatic reactions in confined environments.

Authors:  Andreas Küchler; Makoto Yoshimoto; Sandra Luginbühl; Fabio Mavelli; Peter Walde
Journal:  Nat Nanotechnol       Date:  2016-05-05       Impact factor: 39.213

2.  Trace Oxygen Affects Osmium Redox Polymer Synthesis for Wired Enzymatic Biosensors.

Authors:  Margaret C Calhoun; Christopher D Stachurski; Sara L Winn; Evan A Gizzie; Aaron W Daniel; Nathan D Schley; David E Cliffel
Journal:  J Electrochem Soc       Date:  2022-01-18       Impact factor: 4.386

Review 3.  Emerging synergy between nanotechnology and implantable biosensors: a review.

Authors:  Santhisagar Vaddiraju; Ioannis Tomazos; Diane J Burgess; Faquir C Jain; Fotios Papadimitrakopoulos
Journal:  Biosens Bioelectron       Date:  2009-12-11       Impact factor: 10.618

4.  A Simple Interfacial Platform for Homogeneous Electrochemical Immunoassays Using a Poly(Vinylimidazole)-Modified Electrode.

Authors:  Young-Bong Choi; Won-Yong Jeon; Hyug-Han Kim
Journal:  Sensors (Basel)       Date:  2016-12-29       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.