Literature DB >> 829582

Optimum time of blood sampling for determination of glomerular filtration rate by single-injection [51Cr]EDTA plasma clearance.

J Bröchner-Mortensen, P Rödbro.   

Abstract

We have investigated the influence on reproducibility of total [51Cr]EDTA plasma clearance (E) of various times and number of blood samples in patients with normal (13 patients) and low (14 patients) renal function. The study aims at fixing a clinically useful procedure suitable for all levels of renal function. Six different types of E were evaluated with time periods for blood sampling between 3 and 5h after tracer injection, and the variation from counting radioactivity, sc, was determined as part of total variation, st. Optimum mean time t(E), for blood sampling was calculated as a function of E, as the mean time giving the least change in E for a given change in the 'final slope' of the plasma curve. For patients with normal E, sc did not contribute significantly to ST, and t(E) was about 2h. For patients with low renal function sc contributed significantly to st, and t(E) increased steeply with decreasing E. The relative error of sc from fixed E types was calculated for all levels of renal function. The results indicate that blood sampling individualized according to predicted E values is not necessary. A sufficient precision of E can be achievef for all function levels from three blood samples drawn 180, 240, and 300 min after injection.

Entities:  

Mesh:

Substances:

Year:  1976        PMID: 829582     DOI: 10.3109/00365517609081939

Source DB:  PubMed          Journal:  Scand J Clin Lab Invest        ISSN: 0036-5513            Impact factor:   1.713


  9 in total

1.  Limitations of clearance determination using the single sample distribution volume method. An error analysis on the basis of compartment models.

Authors:  J Kotzerke; W Burchert; H Wiese; U von Smekal; H Hundeshagen
Journal:  Eur J Nucl Med       Date:  1992

2.  Urinary albumin excretion and transcapillary escape rate of albumin in malignancies.

Authors:  L M Pedersen; L Terslev; P G SŁrensen; K H Stokholm
Journal:  Med Oncol       Date:  2000-05       Impact factor: 3.064

3.  Optimal sampling times for minimum variance of clearance determination.

Authors:  M Døssing; A Vølund; H E Poulsen
Journal:  Br J Clin Pharmacol       Date:  1983-02       Impact factor: 4.335

4.  Cystatin C - a fast and reliable biomarker for glomerular filtration rate in head and neck cancer patients.

Authors:  Edwin Bölke; Gisela Schieren; Stephan Gripp; Gerald Steinbach; Matthias Peiper; Klaus Orth; Christiane Matuschek; Maximilian Pelzer; Guido Lammering; Ruud Houben; Christina Antke; Lars Christian Rump; Rodrigo Mota; Peter Arne Gerber; Patrick Schuler; Thomas K Hoffmann; Ethelyn Rusnak; Derik Hermsen; Wilfried Budach
Journal:  Strahlenther Onkol       Date:  2011-02-24       Impact factor: 3.621

5.  Prizidilol, a combined vasodilatory and beta-adrenoceptor blocking drug, in primary hypertension. A long-term efficacy, tolerance and pharmacokinetic study.

Authors:  B E Karlberg; R Larsson; K P Ohman; B Norlander; A Wirsen; J Hed; B L Lundh; A Flock
Journal:  Eur J Clin Pharmacol       Date:  1983       Impact factor: 2.953

6.  A Comprehensive Software and Database Management System for Glomerular Filtration Rate Estimation by Radionuclide Plasma Sampling and Serum Creatinine Methods.

Authors:  Ashish Kumar Jha
Journal:  World J Nucl Med       Date:  2015 May-Aug

7.  Iohexol plasma clearance for measuring glomerular filtration rate in clinical practice and research: a review. Part 1: How to measure glomerular filtration rate with iohexol?

Authors:  Pierre Delanaye; Natalie Ebert; Toralf Melsom; Flavio Gaspari; Christophe Mariat; Etienne Cavalier; Jonas Björk; Anders Christensson; Ulf Nyman; Esteban Porrini; Giuseppe Remuzzi; Piero Ruggenenti; Elke Schaeffner; Inga Soveri; Gunnar Sterner; Bjørn Odvar Eriksen; Sten-Erik Bäck
Journal:  Clin Kidney J       Date:  2016-08-23

8.  No Race-Ethnicity Adjustment in CKD-EPI Equations Is Required for Estimating Glomerular Filtration Rate in the Brazilian Population.

Authors:  Amanda D Rocha; Suzane Garcia; Andressa B Santos; José C C Eduardo; Claudio T Mesquita; Jocemir R Lugon; Jorge P Strogoff-de-Matos
Journal:  Int J Nephrol       Date:  2020-07-18

9.  Accuracy of iohexol plasma clearance for GFR-determination: a comparison between single and dual sampling.

Authors:  Yong Zhang; Zhun Sui; Ze Yu; Tai Feng Li; Wan Yu Feng; Li Zuo
Journal:  BMC Nephrol       Date:  2018-07-11       Impact factor: 2.388

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.