Literature DB >> 8295442

Multiple-scattering effects in transmission oximetry.

I Fine1, A Weinreb.   

Abstract

To develop an algorithm for the spectrophotometric determination of the oxygen saturation in blood, a model for the transmission of light in a scattering and absorbing medium is developed, taking into account effects of multiple scattering. The computed results obtained by a Monte Carlo simulating program agreed well with those found by experiment. The results were compared with those obtained by the commonly used algorithm of transmission oximetry (based on Lambert-Beer's law) and it was found that the calibration curves obtained by this method were strongly dependent on the haematocrit and thickness of the sample. These curves were less reliable the lower the saturation of oxygen.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8295442     DOI: 10.1007/BF02441988

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  12 in total

1.  ANALYSIS OF A MICROMETHOD FOR TRANSMISSION OXIMETRY OF WHOLE BLOOD.

Authors:  E LOEWINGER; A GORDON; A WEINREB; J GROSS
Journal:  J Appl Physiol       Date:  1964-11       Impact factor: 3.531

2.  Transport calculations for light scattering in blood.

Authors:  G D Pedersen; N J McCormick; L O Reynolds
Journal:  Biophys J       Date:  1976-03       Impact factor: 4.033

3.  Diffuse reflectance from a finite blood medium: applications to the modeling of fiber optic catheters.

Authors:  L Reynolds; C Johnson; A Ishimaru
Journal:  Appl Opt       Date:  1976-09-01       Impact factor: 1.980

4.  Spectral transmission and scattering properties of red blood cells.

Authors:  R A MACRAE; J A McCLURE; P LATIMER
Journal:  J Opt Soc Am       Date:  1961-12

5.  Reflection and transmission of light by thin films of nonhaemolysed blood.

Authors:  N M Anderson; P Sekelj
Journal:  Phys Med Biol       Date:  1967-04       Impact factor: 3.609

6.  Optical transmission and reflection by blood.

Authors:  R J Zdrojkowski; N R Pisharoty
Journal:  IEEE Trans Biomed Eng       Date:  1970-04       Impact factor: 4.538

7.  Absorption and multiple scattering by biological suspensions.

Authors:  V Twersky
Journal:  J Opt Soc Am       Date:  1970-08

8.  Role of light scattering in whole blood oximetry.

Authors:  J M Steinke; A P Shepherd
Journal:  IEEE Trans Biomed Eng       Date:  1986-03       Impact factor: 4.538

9.  Theoretical analysis of diffuse reflectance from a two-layer tissue model.

Authors:  S Takatani; M D Graham
Journal:  IEEE Trans Biomed Eng       Date:  1979-12       Impact factor: 4.538

10.  Light-absorbing and scattering properties of nonhaemolysed blood.

Authors:  N M Anderson; P Sekelj
Journal:  Phys Med Biol       Date:  1967-04       Impact factor: 3.609

View more
  1 in total

1.  Multiple scattering effect in transmission pulse oximetry.

Authors:  I Fine; A Weinreb
Journal:  Med Biol Eng Comput       Date:  1995-09       Impact factor: 2.602

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.