Literature DB >> 8295440

Time-varying digital filtering of ECG baseline wander.

L Sörnmo1.   

Abstract

Time-varying filtering techniques are applied to the problem of baseline correction by letting the cut-off frequency of a linear filter be controlled by the low-frequency properties of the ECG signal. The time-varying filter is implemented as a bank of linear low-pass filters, in which each filter has a slightly differing cut-off frequency. Sampling rate decimation and interpolation are employed because the design of a filter for baseline reduction can be treated as a narrowband filtering problem. All filters have a linear phase response to reduce, for example, ST-segment distortion. The performance of the technique presented is studied on ECG signals with different types of simulated baseline wander. The results are compared with the performance of time-invariant linear filtering and cubic spline interpolation. The results show that an improvement in performance can be achieved when using time-varying filtering, especially at low heart rates or during episodes with excessive base-line wander.

Mesh:

Year:  1993        PMID: 8295440     DOI: 10.1007/BF02441986

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  9 in total

1.  Filtering without phase shift.

Authors:  R L Longini; J P Giolma; C Wall; R F Quick
Journal:  IEEE Trans Biomed Eng       Date:  1975-09       Impact factor: 4.538

2.  Recommendations for standardization and specifications in automated electrocardiography: bandwidth and digital signal processing. A report for health professionals by an ad hoc writing group of the Committee on Electrocardiography and Cardiac Electrophysiology of the Council on Clinical Cardiology, American Heart Association.

Authors:  J J Bailey; A S Berson; A Garson; L G Horan; P W Macfarlane; D W Mortara; C Zywietz
Journal:  Circulation       Date:  1990-02       Impact factor: 29.690

3.  Electrocardiogram baseline noise estimation and removal using cubic splines and state-space computation techniques.

Authors:  C R Meyer; H N Keiser
Journal:  Comput Biomed Res       Date:  1977-10

4.  ECG baseline wander reduction using linear phase filters.

Authors:  J A van Alsté; W van Eck; O E Herrmann
Journal:  Comput Biomed Res       Date:  1986-10

5.  Problems and limitations of ECG baseline estimation and removal using a cubic spline technique during exercise ECG testing: recommendations for proper implementation.

Authors:  J N Froning; M D Olson; V F Froelicher
Journal:  J Electrocardiol       Date:  1988       Impact factor: 1.438

Review 6.  Data processing of exercise ECG's.

Authors:  O Pahlm; L Sörnmo
Journal:  IEEE Trans Biomed Eng       Date:  1987-02       Impact factor: 4.538

7.  Delineation of the QRS complex using the envelope of the e.c.g.

Authors:  M E Nygårds; L Sörnmo
Journal:  Med Biol Eng Comput       Date:  1983-09       Impact factor: 2.602

8.  Digital filtering and regression algorithms for an accurate detection of the baseline in ECG signals.

Authors:  F Bartoli; S Cerutti; E Gatti
Journal:  Med Inform (Lond)       Date:  1983 Apr-Jun

9.  Removal of base-line wander and power-line interference from the ECG by an efficient FIR filter with a reduced number of taps.

Authors:  J A Van Alsté; T S Schilder
Journal:  IEEE Trans Biomed Eng       Date:  1985-12       Impact factor: 4.538

  9 in total
  6 in total

1.  Ischemia episode detection in ECG using kernel density estimation, support vector machine and feature selection.

Authors:  Jinho Park; Witold Pedrycz; Moongu Jeon
Journal:  Biomed Eng Online       Date:  2012-06-15       Impact factor: 2.819

2.  Blockwise PPG Enhancement Based on Time-Variant Zero-Phase Harmonic Notch Filtering.

Authors:  Chanki Park; Hyunsoon Shin; Boreom Lee
Journal:  Sensors (Basel)       Date:  2017-04-14       Impact factor: 3.576

3.  Fast time-varying linear filters for suppression of baseline drift in electrocardiographic signals.

Authors:  Jiří Kozumplík; Ivo Provazník
Journal:  Biomed Eng Online       Date:  2017-02-07       Impact factor: 2.819

4.  Multimodal Human and Environmental Sensing for Longitudinal Behavioral Studies in Naturalistic Settings: Framework for Sensor Selection, Deployment, and Management.

Authors:  Brandon M Booth; Karel Mundnich; Tiantian Feng; Amrutha Nadarajan; Tiago H Falk; Jennifer L Villatte; Emilio Ferrara; Shrikanth Narayanan
Journal:  J Med Internet Res       Date:  2019-08-20       Impact factor: 5.428

Review 5.  Timing errors and temporal uncertainty in clinical databases-A narrative review.

Authors:  Andrew J Goodwin; Danny Eytan; William Dixon; Sebastian D Goodfellow; Zakary Doherty; Robert W Greer; Alistair McEwan; Mark Tracy; Peter C Laussen; Azadeh Assadi; Mjaye Mazwi
Journal:  Front Digit Health       Date:  2022-08-18

6.  A hierarchical method for removal of baseline drift from biomedical signals: application in ECG analysis.

Authors:  Yurong Luo; Rosalyn H Hargraves; Ashwin Belle; Ou Bai; Xuguang Qi; Kevin R Ward; Michael Paul Pfaffenberger; Kayvan Najarian
Journal:  ScientificWorldJournal       Date:  2013-05-20
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.