Unipolar ventricular electrograms were recorded in the right ventricular apical area in five patients with clinical, hemodynamic features of the right ventricular infarction. The intracavitary potential exhibited a downward displacement of the ST segment (1.5 mV). This significant negative current of injury in the ventricular electrogram is consistent with ischemic injury of the free right ventricular wall in the area subtended by the intracavitary exploring electrode. We suggest that ventricular electrographic recordings be performed in patients who present with acute inferior wall infarction requiring temporary electrode catheter pacing for serious AV conduction disturbances. The presence of a significant downward ST segment displacement (1.5 mV) provides further support and an electrical criterion for right ventricular ischemic injury.

Entities:  

Mesh:

Year:  1978        PMID: 82951     DOI: 10.1111/j.1540-8159.1978.tb03488.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  4 in total

1.  Combining current of injury and P-wave sensing optimized right atrial active-fixation leads implantation.

Authors:  Meng-Rong Chen; Fei-Long Zhang; Wei-Wei Wang; Xue-Hai Chen; Jian-Hua Chen; Liang-Long Chen
Journal:  J Thorac Dis       Date:  2019-04       Impact factor: 2.895

Review 2.  The AngelMed Guardian® System in the Detection of Coronary Artery Occlusion: Current Perspectives.

Authors:  Syed Hassan Abbas Kazmi; Sudarshana Datta; Gerald Chi; Tarek Nafee; Megan Yee; Akshun Kalia; Sadaf Sharfaei; Fahimehalsadat Shojaei; Sabawoon Mirwais; C Michael Gibson
Journal:  Med Devices (Auckl)       Date:  2020-01-07

3.  Morphology of current of injury does not predict long term active fixation ICD lead performance.

Authors:  Hanno Oswald; Benjamin Husemann; Ajmal Gardiwal; Christoph Lissel; Maximilian A Pichlmaier; Ulrich Luesebrink; Thorben Koenig; Gunnar Klein
Journal:  Indian Pacing Electrophysiol J       Date:  2009-03-15

4.  Time course of current of injury is related to acute stability of active-fixation pacing leads in rabbits.

Authors:  Shalaimaiti Shali; Alimujiang Wushou; Entao Liu; Lin Jia; Ruiming Yao; Yangang Su; Junbo Ge
Journal:  PLoS One       Date:  2013-03-05       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.