Literature DB >> 8294820

Poor correlation between functional results and radiographic findings in Colles' fracture.

T Tsukazaki1, K Takagi, K Iwasaki.   

Abstract

We reviewed 83 consecutive patients with unilateral Colles' fracture in order to identify factors that predict poor functional outcome. All fractures were treated by closed reduction and cast immobilization, and followed-up for at least 2 years. Our results showed that only final dorsal angulation was correlated to loss of flexion. In contrast to other reports, we could not find any relationship between radial shortening and loss of grip strength or loss of range of motion. In addition, the severity of initial displacement, involvement of radio-carpal or distal radio-ulnar joints, and the presence of ulnar styloid fractures or their non-union did not affect the functional outcome.

Entities:  

Mesh:

Year:  1993        PMID: 8294820     DOI: 10.1016/0266-7681(93)90010-d

Source DB:  PubMed          Journal:  J Hand Surg Br        ISSN: 0266-7681


  9 in total

1.  A comparative study of Colles' fractures in patients between fifty and seventy years of age: percutaneous K-wiring versus volar locking plating.

Authors:  Yih-Shiunn Lee; Tien-Yung Wei; Yu-Chieh Cheng; Tzu-Liang Hsu; Chien-Rae Huang
Journal:  Int Orthop       Date:  2011-12-13       Impact factor: 3.075

2.  Radiological dorsal tilt analysis of AO type A, B, and C fractures of the distal radius treated conservatively or with extra-focal K-wire plus external fixateur.

Authors:  Michael Hoffmann; Malte Schroeder; Kai Kossow; Michaela Gruber-Rathmann; Andreas H Ruecker
Journal:  Skeletal Radiol       Date:  2012-02-05       Impact factor: 2.199

3.  Distal radius fractures: does a radiologically acceptable reduction really change the result?

Authors:  Niraj Ranjeet; Emmanuel P Estrella
Journal:  J Clin Diagn Res       Date:  2012-10

4.  Anterior fracture displacement in Colles' fractures after Kapandji wiring in women over 59 years.

Authors:  Nadine Hollevoet; René Verdonk
Journal:  Int Orthop       Date:  2006-07-25       Impact factor: 3.075

5.  Radiographs late in the follow up of uncomplicated distal radius fractures: are they worth it? Clinical outcome and financial implications.

Authors:  Nicholas Eastley; Randeep Aujla; Zeeshan Khan
Journal:  Orthop Rev (Pavia)       Date:  2012-06-13

6.  Is there a correlation between functional results and radiographic findings in patients with distal radius fracture A0 type A3 treated with volar locking plate or external fixator?

Authors:  Trine Ludvigsen; Kjell Matre; Nils Vetti; Per Martin Kristoffersen; Monika Kolskår Toppe; Rakel Gudmundsdottir; Yngvar Krukhaug; Eva Dybvik; Jonas Meling Fevang
Journal:  OTA Int       Date:  2021-08-09

7.  Radiological and functional outcome in extra-articular fractures of lower end radius treated conservatively with respect to its position of immobilization.

Authors:  Sunil Rajan; Saurabh Jain; A Ray; P Bhargava
Journal:  Indian J Orthop       Date:  2008-04       Impact factor: 1.251

8.  SURGICAL TREATMENT OF DISTAL RADIUS FRACTURES WITH A VOLAR LOCKED PLATE: CORRELATION OF CLINICAL AND RADIOGRAPHIC RESULTS.

Authors:  Claudio Roberto Martins Xavier; Danilo Canesin Dal Molin; Rafael Mota Marins Dos Santos; Roberto Della Torre Dos Santos; Julio Cezar Ferreira Neto
Journal:  Rev Bras Ortop       Date:  2015-12-06

9.  STATISTICAL ANALYSIS ON FUNCTIONAL AND RADIOGRAPHIC RESULTS AFTER USE OF LOCKED VOLAR PLATE FOR FRACTURES OF THE DISTAL RADIUS.

Authors:  Daniel Gonçalves Machado; Sergio Auto da Cruz Cerqueira; Rodrigo Ribeiro Pinho Rodarte; Carlos Alberto de Souza Araújo Netto; Marcelo Bezerra de Mathias
Journal:  Rev Bras Ortop       Date:  2015-12-06
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.