Strategies for coupling digital filtering with partial least-squares regression: application to the determination of glucose in plasma by Fourier transform near-infrared spectroscopy.

G W Small1, M A Arnold, L A Marquardt.   

Abstract

Protocols are established for coupling digital filtering techniques with partial least-squares (PLS) regression for use in constructing multivariate calibration models from Fourier transform near-infrared absorbance spectra. Calibration models are developed to predict glucose concentrations in bovine plasma samples. Employing a calibration data set of 300 spectra collected from 55 plasma samples and 3 plasma lots, individual calibration models are developed based on four spectral ranges selected from the region 5000-4000 cm-1. A separate test set of 69 spectra collected from 14 plasma samples is used to evaluate the computed models. Gaussian-shaped bandpass digital filters are implemented by use of Fourier filtering techniques and employed to preprocess spectra to remove variation due to the background absorbance of the plasma matrix. PLS regression is used with the filtered spectra to compute calibration models for glucose. The optimization of the filter bandpass parameters is explored through the use of response surface methods. Through these optimization studies, calibration models are developed that achieve standard errors of estimate and standard errors of prediction in the range 0.4-0.5 mM across the concentration range of 2.5-25.5 mM. It is determined that the use of digital filtering as a preprocessing step significantly improves the performance of the resulting calibration models, minimizes the importance of spectral range in the calibration model development, and reduces the required number of PLS factors in each model.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8291679     DOI: 10.1021/ac00070a019

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  4 in total

1.  In vivo glucose monitoring using dual-wavelength polarimetry to overcome corneal birefringence in the presence of motion.

Authors:  Casey W Pirnstill; Bilal H Malik; Vincent C Gresham; Gerard L Coté
Journal:  Diabetes Technol Ther       Date:  2012-06-12       Impact factor: 6.118

2.  Simultaneous measurement of glucose and glutamine in aqueous solutions by near infrared spectroscopy.

Authors:  H Chung; M A Arnold; M Rhiel; D W Murhammer
Journal:  Appl Biochem Biotechnol       Date:  1995-02       Impact factor: 2.926

3.  Clinical evaluation of a transcutaneous interrogated fluorescence lifetime-based microsensor for continuous glucose reading.

Authors:  Jannik K Nielsen; Jens S Christiansen; Jesper S Kristensen; Hans O Toft; Lars Lundby Hansen; Søren Aasmul; Klaus Gregorius
Journal:  J Diabetes Sci Technol       Date:  2009-01

4.  Study of Two Constraints Impacting Measurements of Human Glycemia Using a Microwave Sensor.

Authors:  Mohamed Amine Zidane; Hichem Amar; Amar Rouane
Journal:  Biosensors (Basel)       Date:  2021-03-15
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.